Model reference
Amana CR5-1
Air Conditioner
1 document28 error codes7 service modes
Available documentation
Installation Guide
- Installation Instructions6 pg
MyPros+ Max
Diagnose your Amana CR5-1.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (28)
CodeMeaning
BURNER HIGH LIMIT FAULTIndicates the temperature disk in the burner has opened (tumbler hi-limit has…BURNER IGNITION CONTROL FAULTNo signal to gas valve from Direct Spark Ignition (DSI) module during trial for…BURNER PURGE FAULTThe gas valve signal is present during the prepurge time.dSFLIndicates a loose connection on sensor probe wiring when power is reestablished…EE PROM FAULT ###Error in memory location; the ### indicates the location of the fault.EXHAUST HIGH LIMIT FAULTIndicates the temperature disk in the exhaust has opened.EXHAUST HIGH TEMP FAULTIndicates the temperature in the tumbler is above 220°F (104°C).F1Indicates a failed component in the Electronic Range Control (ERC).F2Sensor resistance too high.F3Open wire lead in sensor harness, bad harness/sensor connection, or sensor…F4Sensor resistance too low (below 500 ohms).F5Indicates a failed component in the ERC.F6Indicates a failed component in the ERC or caused by fluctuations in 60 Hz…F7Indicates a shorted or sticking contact in one or more of the function control…F8Indicates a failed component in the ERC.F9Door Latch Supervisory failureFLAME FAULTFlame was detected during trial for ignition but failed sometime after; must…IGNITION FAULTGas valve did not remain open after trial for ignition; indicates that no flame…LINT ACCESS OPENIndicates the lint drawer is open and needs to be closed.LOW VOLTAGE FAULTIndicates power has dropped below the operating values and will shutdown.MAIN DOOR OPENEDA main door is open when it should be closed.MODEL ERRORThe wrong model was selected for the dryer.MODEL ERROR, ENTER CORRECT MODELThe wrong model was selected for the dryer.OPEN EXHAUST TEMPERATURE PROBEIndicates the exhaust temperature probe is open or shorted.OPEN S.A.F.E. SYSTEM PROBE FAULTIndicates the temperature probe for the S.A.F.EROTATION FAULTIndicates the tumbler is not rotating.SAIL SWITCH CLOSED FAULTSail switch is closed when it should be open (prior to start up).SAIL SWITCH OPEN FAULTSail switch is open when it should be closed (opened during heating mode).Service modes (7)
- Display Test / Sales Demonstration Mode (One Piece ERC)["Clock must previously be set for the time of day.","Press and hold the CLOCK button until TIME is…
- Display Test / Sales Demonstration Mode (Two Piece ERC)["Clock must previously be set for the time of day.","Press and hold the CLOCK button until TIME is…
- ERC Temperature Calibration Mode (One Piece Control)["Press and release the BAKE TEMP function button.","Rotate the TIME/TEMP SET knob clockwise until…
- ERC Temperature Calibration Mode (Two Piece Control)["Press and release the BAKE TEMP function button.","Rotate the TIME/TEMP SET knob clockwise until…
- Military Time Toggle (Slide In Clock/Timer)["Simultaneously press COOK/CLEAN TIME button and STOP TIME button to toggle between standard AM/PM…
- S.A.F.E. System Check["Ensure all water supply shutoff valves to the dryer are in the OPEN position.","Dryer must be in…
- S.A.F.E. System Check Procedure["Ensure dryer is in READY mode with no cycle loaded or in progress.","Ensure all water supply…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana air conditioner models
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax