Model reference

Amana CR5-3/P55201-5C

Air Conditioner

39 error codes10 service modes
MyPros+ Max

Diagnose your Amana CR5-3/P55201-5C.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (39)

CodeMeaning
F1Internal board failure (LCC 90/95)F1.E1Relay Control Board defective.F1E0Internal board failure.F1E1Indicates a CCU (Cycle Control Unit) problem.F1E2Internal board failure.F2A/D Error(s)F2.H1Hood/light switch stuck.F2.H2Hood/light switch error.F2.Q1User interface board (UIB) is not reading keypad inputs.F2E0Shorted key.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F3Oven sensor opened or shorted, or bake/broil/clean range over temperature (LCC…F3.H1Humidity sensor failure.F3.T1UIB (user interface board) thermistor failure.F3.T4Magnetron thermistor failure.F3E0Oven sensor opened.F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in Diagnostic Test Mode.F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F5Door and switches do not agree or door latch not operating during clean mode…F5E0Door and switches do not agree (clean mode).F5E1Door latch not operating (clean mode).F5E2Door and switches do not agree (clean mode).
View all 39 error codes

Service modes (10)

  • Customer-Focused Dryness Level Adjustment1
  • Diagnostics ModePress CANCEL > CANCEL > START within a 5-second period.
  • Diagnostics Test Mode (Relay Checks)While in Diagnostics Mode, press individual keypads to test control relays
  • Electronic Oven Control Test["1. Unplug the oven.","2. Remove the cabinet.","3. Discharge the HV capacitor with a 20,000 ohm…
  • Install Diagnostics1
  • Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
  • Service Diagnostic Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Select any three buttons…
  • Software Version Display1
  • Temperature Adjustment ModeStep 1
  • Touch Panel Test Mode["1

Full entry steps, exit procedures, and test sequences are available in Max.

75,000+ service documents · 20,000+ error codes · 100+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax