56 error codes19 service modes
MyPros+ Max

Diagnose your Amana ECFC48HOH-A/P68598-4C.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (56)

CodeMeaning
:Flashing colon indicates a power failure has occurred.AFRestricted airflow condition exists.F-01Primary control failure.F-02Stuck button or user interface mismatch (only appears in diagnostic test mode).F-22Exhaust thermistor is open.F-23Exhaust thermistor has shorted.F-24Inlet thermistor is open (only appears in diagnostic test mode).F-25Inlet thermistor is shorted (only appears in diagnostic test mode).F-26Motor drive system failure.F-28Moisture sensor strip is open (only appears in diagnostic test mode).F-29Moisture sensor strip has shorted (only appears in diagnostic test mode).F-30Restricted airflow condition exists (only appears in diagnostic test mode).F-50No voltage detected at the water valve relay (steam models only, only appears…F:01Primary control failure.F:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Outlet thermistor is open.F:23Outlet thermistor has shorted.F:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).F:25Inlet thermistor has shorted (appears ONLY in Diagnostic Test Mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).F:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).F:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).F:31Low voltage condition (less than 30V) detected (appears ONLY in Diagnostic Test…F:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure (F:72 through F:78).F:73Console electronics failure (F:72 through F:78).
View all 56 error codes

Service modes (19)

  • customer_focused_drying_mode_adjustment1
  • Customer-Focused Drying Mode Adjustment1
  • Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)1
  • Customer-Focused Dryness Level Adjustment1
  • Diagnostic Test Mode1
  • diagnostic_test_mode1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Done…
  • display_line_voltageAfter all saved fault codes have been displayed in diagnostic test mode, press the End of Cycle…
  • Inlet Air Flow Test (Electric Models Only)After entering Diagnostic Test Mode and cycling through saved fault codes, press the Wrinkle Guard…
  • Install Diagnostics1
  • Line Voltage Display TestAfter entering Diagnostic Test Mode and cycling through saved fault codes, press the Cycle Signal…
  • Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
  • Manual Load Test1. Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Dry…
  • manual_load_test1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Done…
  • Quick Diagnostic TestFrom Service Diagnostics, navigate to Error Diagnostic > Quick Diagnostic Test
  • Service Diagnostic Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Select any three buttons…
  • Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
  • Software Version Display1
  • Touch Panel and Electronic Control Test (Diagnostic/Test Mode)["Press and hold the OFF/CANCEL button while opening the door.","While still holding the OFF/CANCEL…
  • UI Component TestFrom Service Diagnostics, navigate to Component Activation > UI Component Test