Model reference

Amana ERHQ30-W01B/P68522-3C

Air Conditioner

2 documents40 error codes17 service modes

Available documentation

Tech Tip

  • Instruction Sheet - 8533777 - Rev A8 pg
    Covers this model
  • Instruction Sheet - 39800578 pg
    Covers this model
MyPros+ Max

Diagnose your Amana ERHQ30-W01B/P68522-3C.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (40)

CodeMeaning
AFLow inlet air flow detected at install.E1Thermistor is open.E2Thermistor has shorted.E3User interface or software mismatchF:01Primary control failure.F:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Outlet thermistor is open.F:23Outlet thermistor has shorted.F:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).F:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).F:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).F:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).F:31Low voltage condition (less than 30V) detected (appears ONLY in Diagnostic Test…F:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure (F:72 through F:78).F:73Console electronics failure (F:72 through F:78).F:74Console electronics failure (F:72 through F:78).F:75Console electronics failure (F:72 through F:78).F:76Console electronics failure (F:72 through F:78).F:77Console electronics failure (F:72 through F:78).F:78Console electronics failure (F:72 through F:78).F1Control failure or UL A/D error(s) detected in the control board.F1 E*Control board failure (all F1 sub-codes indicate control fault).F2Shorted/stuck key detected on the control keypad.F3Oven sensor opened or oven sensor shorted.
View all 40 error codes

Service modes (17)

  • Console Diagnostics - Switches and Indicators["Enter diagnostic test mode (see above).","Press each button or turn the cycle selector to each…
  • Console Diagnostics (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode as described above.","Press each button or turn the cycle selector…
  • Customer-Focused Drying Mode Adjustment["In Standby mode (dryer plugged in but not powered up), press and hold the Dryness Level button…
  • Diagnostic - Door Switch["Enter diagnostic test mode.","Open the door
  • Diagnostic - Moisture Sensor["Enter diagnostic test mode.","Locate two metal strips on the face of the lint screen…
  • Diagnostic Test Mode["Ensure the dryer is in standby mode (plugged in and all indicators off).","Within 5 seconds…
  • Door Switch Diagnostic (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode.","Open the door
  • Inlet Air Flow Diagnostic (Electric Models Only)["Enter Diagnostic Test Mode and wait for 5-second delay.","Cycle through any saved fault…
  • LCC Diagnostic Mode (LCC90/LCC95/LCC180)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
  • LCC190 Diagnostic Mode (Self Clean, Convection models)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME or TEMP/HOUR '+' key to cycle through…
  • Line Voltage Diagnostic["Enter Diagnostic Test Mode and wait for 5-second delay.","Cycle through any saved fault…
  • Manual Load Test["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Done…
  • Moisture Sensor Diagnostic (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode.","Locate two metal strips on the face of the lint screen…
  • MRC Diagnostic Mode["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
  • MRC Diagnostic Mode (Fan/True Convection Electric - Oven Light entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
  • MRC II Diagnostic Mode (Number 3 key entry - KitchenAid models)["Press OFF/OFF/START or CANCEL/CANCEL/START in sequence.","Press the number '3' key to cycle…
  • MRC II Diagnostic Mode (TEMP/TIME entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' keypad to cycle through diagnostic…

Full entry steps, exit procedures, and test sequences are available in Max.