Model reference
Amana SCFC60HOH-A/P68598-9C
Air Conditioner
7 documents25 error codes11 service modes
Available documentation
Tech Sheet
- Tech Sheet - W10403269 - Rev A52 pg
Installation Guide
- Installation Instructions24 pg
- Installation Instructions32 pg
- Installation Instructions4 pg
- Installation Instructions17 pg
- Installation Instructions16 pg
- Installation Instructions30 pg
MyPros+ Max
Diagnose your Amana SCFC60HOH-A/P68598-9C.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (25)
CodeMeaning
2-1Key switch stuck closed for more than 30 seconds.2-2Over temperature alarm.2-3Long black out alarm.2-4Door alarm.3-1Fridge evaporator sensor issue.3-2Fridge ambient sensor issue.3-3Freezer ambient sensor issue.4-1Heater failure.F1E1Indicates a Cycle Control Unit (CCU) problem.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F2E2User Interface software errorF3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<20 ohms).F3E5Inlet and exhaust thermistors are open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in service diagnostic…F4E3Restricted/low air flow that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at installation.F6E1Communication error from UI to CCU; communication between CCU and UI has not…F6E2Communication error from CCU to UI; communication between CCU and UI has not…L2Low L2 voltage (less than 50V) detected at installation.PFPower failure occurred while the dryer was running.Service modes (11)
- Customer-Focused Dryness Level Adjustment1
- diagnosticStandby Method
- diagnostic_alternative1) Unplug the refrigerator. 2) Wait 20 seconds. 3) Plug back in. 4) Within 30 seconds, press…
- failure_historyEntered automatically after KEY test
- Install Diagnostics1
- key_testAutomatically enters after service test activation
- Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
- loads_and_sensor_testEntered after failure history step
- Service Diagnostic Mode1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
- Software Version Display1
- User Interface/Control System Test1. Activate Service Diagnostic Mode. 2. Press and release the 1st button used to activate Service…
Full entry steps, exit procedures, and test sequences are available in Max.