Model reference
Amana VBC30CT-1W/P55572-1C
Air Conditioner
7 documents37 error codes16 service modes
Available documentation
Tech Sheet
- Tech Sheet - 1602629110 pg
- Tech Sheet - 160225099 pg
Installation Guide
- Instrucciones de instalacion16 pg
- Instrucciones de instalacion28 pg
- Installation Instructions16 pg
- ventilation-specification-W10200920D.pdf8 pg
- Installation Instructions16 pg
MyPros+ Max
Diagnose your Amana VBC30CT-1W/P55572-1C.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (37)
CodeMeaning
1c1cShorted key detected on control circuit board.1c2cKeyboard tail disconnected; keyboard loop improper value.1c31Cancel key circuit problem; cancel key improper value.1c32Cancel key circuit problem; cancel key improper value.1c4cPower micro communication failure1c6cEEPROM error; no response from EEPROM after 3 tries.1c7cControl not calibrated; calibration value out of range.1c81Cook profile corrupted in EEPROM for upper oven1c82Cook profile corrupted in EEPROM for lower oven1c8cCooking program error; CRC invalid.1d11Runaway temperature (650°F) detected, door unlocked; sensor resistance > 2237…1d12Runaway temperature (650°F) detected, door unlocked; sensor resistance > 2237…1d21Runaway temperature (950°F) detected, door locked; sensor resistance > 2787…1d22Runaway temperature (950°F) detected, door locked; sensor resistance > 2787…3d11Temperature sensor open; sensor resistance reads infinite Ohms.3d12Temperature sensor open; sensor resistance reads infinite Ohms.3d21Temperature sensor shorted; sensor resistance reads 0 Ohms.3d22Temperature sensor shorted; sensor resistance reads 0 Ohms.3d41Meat probe shorted3d51Meat probe not calibrated4d11Door switch position failure; door switch not closed when door is locked.4d12Door switch position failure; door switch not closed when door is locked.4d21No reverse airflow fan rotation (no or low RPM).4d22No Reverse Airflow Fan rotation (no/low RPM) in lower oven.4d31Reverse airflow fan state error (on when it should be off).4d32Reverse Airflow Fan state error in lower oven (on when supposed to be off).4d41High Reverse Airflow Fan rotation (high RPM) in upper oven.4d42High Reverse Airflow Fan rotation (high RPM) in lower oven.4d51Door switch circuit failure; door switch not open or closed.4d52Door switch circuit failure; door switch not open or closed.View all 37 error codes
5a6Sabbath Mode active status indicator (not a fault code).9d11Latch will not lock; lock switch not closed.9d12Latch will not lock; lock switch not closed.9d21Latch will not unlock; unlock switch not closed.9d22Latch will not unlock; unlock switch not closed.9d31Latch state unknown; both locked and unlocked switches indicate active…9d32Latch state unknown; both locked and unlocked switches indicate active…
Service modes (16)
- 24-Hour Clock TogglePress Cancel and Favorite pads simultaneously for 5 seconds.
- Child LockoutPress and hold Cancel and Cook & Hold pads for 3 to 5 seconds
- Clock Display Disable/EnablePress and hold Cancel and Clock pads simultaneously for 5 seconds.
- Clock Display TogglePress and hold Cancel and Clock pads for 3 to 5 seconds.
- Control LockPress Cancel and Cook & Hold pads simultaneously for 5 seconds to enable.
- Control Lockout["Press and hold BACK and ENTER pads for 5 seconds."]
- Diagnostic Code DisplayPress and hold the Autoset 0 pad for 5 seconds while powering up the unit
- Diagnostic Code Display Mode["Press SETUP pad.","Press DOWN ARROW pad three times until SERVICE is displayed.","Press SERVICE…
- Factory Default ResetPress and hold Cancel and Keep Warm pads simultaneously for 5 seconds.
- Oven Temperature AdjustmentPress Bake pad and enter 550°F
- Quick TestPress and hold the Cancel and Broil pads simultaneously for 5 seconds at power-up, or within 5…
- Sabbath ModeHold CLOCK pad for 3 to 5 seconds to activate Sabbath mode
- Temperature Display Toggle (°F/°C)Press and hold Cancel and Bake pads simultaneously for 5 seconds.
- Temperature Display Toggle (F/C)Press and hold Cancel and Bake pads for 3 to 5 seconds.
- Test Mode["Press SETUP pad.","Press DOWN ARROW pad three times until SERVICE is displayed.","Press SERVICE…
- Twelve Hour Off / Sabbath ModePress and hold Clock pad for 5 seconds.
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana air conditioner models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass