Error codes (36)
CodeMeaning
1-1Control detected K2 pilot relay stuck closed.1-2Damaged or corrupted memory on control board, or incompatible software…10-1Dispenser electrical problem; loose connection in dispenser circuit and/or open…10-2Vent wax motor electrical problem; loose connection in vent circuit and/or open…10-3Drying fan error; loose connection in fan circuit and/or open fan motor.2-1Stuck key(s) detected in keypad or keypad connection.2-2User interface cannot communicate with the main control board; incorrect…3-1Open connector or component in temperature sensing circuit; open or faulty…3-2Incoming water temperature above 167°F (75°C), or shorted connection/component…3-3OWI failed calibration.4-3Wash motor not running due to loose connection in wash motor circuit and/or…5-1Door stuck open; door was not latched within 3 seconds of pressing Start/Resume…5-2Door stuck closed; control programmed to not start if it suspects door switch…6-1Low/no water (mechanical problem); no water supply to dishwasher or various…6-2Fill valve electrical problem; loose connection in fill valve circuit and/or…6-3Suds/air in pump; too many suds, captured wash water, water leak, or missing…6-4Float switch open; overfill switch stuck in overfill position and/or dishwasher…6-7Disconnected or damaged flowmeter.6-8Regen valve electrical problem; loose connection in regen valve circuit and/or…7-1No heat; control programmed to disable heater but continue running cycles if it…7-2Heater stuck on; heater drive circuit on the control is faulty.8-1Slow drain; obstructed drain hose or path, or drain pump impeller fractured.8-2Drain motor electrical problem; loose connection in drain motor circuit and/or…8-3Drain stuck on; drain motor drive circuit on the control is faulty.9-1Can't find diverter position; corroded or loose connection in diverter…9-2Diverter stuck on; diverter drive circuit on the control is faulty.9-3Control detected diverter disk in sump is missing.9-4Lower spray arm error; mechanical blockage or jammed lower spray arm, or…F-01Primary control failure.F-02Stuck button or user interface mismatch (keypad/user interface failure).View all 36 error codes
F-22Exhaust thermistor is open.F-23Exhaust thermistor has shorted.F-26Motor drive system failure.F-28Moisture sensor strip is open (only appears in diagnostic test mode).F-29Moisture sensor strip has shorted (only appears in diagnostic test mode).PFPower failure occurred while the dryer was running.
Service modes (5)
- diagnostic1. Ensure dryer is in standby mode (plugged in with all indicators off, or only Cycle Complete…
- Diagnostic Test Mode1. Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Cycle…
- Dryness Adjust Mode (Customer-Focused Drying Modes)1
- dryness_adjust1
- Service Diagnostics CycleWhile in standby, press any 3 keys in the sequence 1-2-3-1-2-3-1-2-3 with no more than 1 second…