Model reference
Amana AKC-4B
Cooktop
4 documents60 error codes21 service modes
Available documentation
Tech Sheet
- TECH SHEET - 9759688 - Rev A6 pg
- Tech Sheet - W100465908 pg
Tech Tip
- Instruction Sheet - 818477712 pg
Other
- R0233001_R0233001168 pg
MyPros+ Max
Diagnose your Amana AKC-4B.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (60)
CodeMeaning
AFLow inlet air flow detected at install.F-01Primary control failure.F-02Stuck button or user interface mismatch (only appears in diagnostic test mode).F-22Exhaust thermistor is open.F-23Exhaust thermistor has shorted.F-26Motor drive system failure.F-28Moisture sensor strip is open (only appears in diagnostic test mode).F-29Moisture sensor strip has shorted (only appears in diagnostic test mode).F-50No voltage detected at the water valve relay (steam models only, only appears…F:01Primary control failure.F:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Outlet thermistor is open.F:23Outlet thermistor has shorted.F:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).F:25Inlet thermistor has shorted (appears ONLY in Diagnostic Test Mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).F:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).F:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).F:31Low voltage condition (less than 30V) detected (appears ONLY in Diagnostic Test…F:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure (F:72 through F:78).F:73Console electronics failure (F:72 through F:78).F:74Console electronics failure (F:72 through F:78).F:75Console electronics failure (F:72 through F:78).F:76Console electronics failure (F:72 through F:78).F:77Console electronics failure (F:72 through F:78).View all 60 error codes
F:78Console electronics failure (F:72 through F:78).F0 E0No error(s) foundF0-E0No failure present (displayed only when user presses and holds CANCEL/OFF for 5…F1 E0EEPROM communications error.F1 E1EEPROM checksum failure.F1 E2UL A/D error(s).F1-E0EEPROM communications failure.F1-E1EEPROM checksum failure.F2Touch panel failure.F2 E0Shorted key / Stuck key.F2 E1Keytail unplugged.F2-E0Fuel type (gas/electric) select failure.F3 E0Oven sensor opened.F3 E1Oven sensor shorted.F3 E2BAKE/BROIL range over temperature.F3 E3CLEAN range over temperature.F3-E0Key held down too long or shorted key.F3-E1Keytail unplugged or damaged.F3-E2BAKE/BROIL range over temperature condition.F3-E3CLEAN range over temperature condition.F3-E6CANCEL key failure.F5 E0Door latch and switches do not agree.F5 E1Door latch not operating.F5 E2Latch error during CLEAN.F5-E0Door switches do not agree.F5-E1Door latch not operating.F5-E2Latch error during CLEAN cycle.F6Microwave relay failure.L2Low line voltage (less than 30V) detected at installation.PFPower failure occurred while the dryer was running.
Service modes (21)
- 12 Hour Shut-OffPress and hold TIMER OFF key for 5 seconds.
- Audible Signal Pitch ControlPress and hold DELAY START key for 5 seconds.
- Cooktop Lockout FeaturePress and hold TOP/TOP LIGHT keypad for 5 seconds
- Customer-Focused Drying Mode Adjustment1
- Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)1
- Diagnostic Test Mode1
- Disable/Enable All Tones (except end-of-timer and error tones)Press and hold COOK TIME key for 5 seconds.
- Disable/Enable Cycle and Timer-End Repeating TonesPress and hold TIMER SET key for 5 seconds.
- Fahrenheit to Celsius TogglePress and hold BROIL key for 5 seconds.
- Fuel Type VerificationPress and hold START/ENTER key for 5 seconds
- Inlet Air Flow Test (Electric Models Only)After entering Diagnostic Test Mode and cycling through saved fault codes, press the Wrinkle Guard…
- Last fault code retrievalPress and hold CANCEL/OFF key for 5 seconds to display the last error code.
- Line Voltage Display TestAfter entering Diagnostic Test Mode and cycling through saved fault codes, press the Cycle Signal…
- Manual Load Test1. Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Clothes…
- Recall Last Failure CodePress and hold CANCEL/OFF key for 5 seconds
- Sales Demonstration ModePress and hold START/ENTER key for 5 seconds.
- Software Revision NumberPress and hold TIME key for 5 seconds.
- Temperature Adjustment (Calibration)Press and hold BAKE pad for 5 seconds
- Temperature Calibration OffsetPress and hold BAKE pad for 5 seconds. Current offset is shown in 3-digit display; 'CAL' is shown…
- Test modeWithin 60 seconds of power up, simultaneously hold down the BAKE and CLOCK keys for 5 seconds
- Touch Panel and Electronic Control Self-Diagnostic Test Mode["Press and hold OFF/CANCEL while opening the door.","While still holding the OFF/CANCEL button…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana cooktop models
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass