Model reference
Amana C7-AG/P60116-32WG
Freezer
63 error codes17 service modes
MyPros+ Max
Diagnose your Amana C7-AG/P60116-32WG.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (63)
CodeMeaning
dLDoor/lid cannot lockdUDoor/lid cannot unlockF-01Primary control failure.F-02Stuck button or user interface mismatch (only appears in diagnostic test mode).F-22Exhaust thermistor is open.F-23Exhaust thermistor has shorted.F-26Motor drive system failure.F-28Moisture sensor strip is open (only appears in diagnostic test mode).F-29Moisture sensor strip has shorted (only appears in diagnostic test mode).F-30Restricted airflow condition exists (only appears in diagnostic test mode).F-40Communication between machine control and motor control is lost.F-41Blower motor failure.F-42Motor control detects voltage less than 90 VAC (undervoltage failure).F-43Motor control detects a low voltage condition (undervoltage warning); dryer…F-44Motor control electronics failure.F-45Motor control electronics speed sensor failure.F-46Motor control detects an over-current or over-torque condition.F1Primary control failure.F1E1Indicates a Cycle Control Unit (CCU) problem.F2Keypad/User Interface failureF2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F2E2UI cannot read EEPROM software from the User Interface.F30Saved fault code for Long Fill (LF).F32Saved fault code for Long Drain (Ld).F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<20 ohms).F3E5Inlet and exhaust thermistors are open; occurs if the P4/P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.View all 63 error codes
F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F40ATC thermistor detected to be open or shorted.F41Motor rotor position sensor (RPS) thermistor detected to be open or shorted.F42Heater thermistor is open or shorted (not used on these models).F4E1No voltage detected at the heater relay; only appears in service diagnostic…F4E3Restricted/low air flow that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at installation.F50Motor stalledF51Motor rotor position sensor (RPS) failure.F52Motor stop failureF53Motor control over-temperatureF54Motor control overcurrentF60Saved fault code for Primary Control Failure.F68Saved code for Primary Control Failure (range F60-F68).F70Saved fault code for Overloaded (oL).F71Saved fault code for Suds Detection (Sd).F72Basket re-engagement failureF80Saved fault code for Door Lock Failure (dL).F81Saved fault code for Open/Close Door Lid (lid).F82Saved fault code for Door Lock Failure (dL).F83Saved fault code for Door Unlock Failure (dU).F84Saved fault code for Door Lock Failure (dL).F85Saved fault code for Door Lock Failure (dL).HCHot and cold inlet hoses are reversed.L2Low L2 voltage (less than 50V) detected at installation.LdWasher is taking too long to drainLFWasher is taking too long to filllidLid openedoLOverloadedPFPower failure occurred while the dryer was running.PoPump outSdSuds detecteduLUnbalanced load detected
Service modes (17)
- Automatic Diagnostic Test Mode1
- Console and Indicators Diagnostic Test Mode1. Plug in washer or reconnect power. 2. From Standby (Off) Mode, press and release the following…
- customer_focused_drying_mode_adjustment["Press and hold the Dryness button for 5 seconds.","Dryer beeps and displays CF for one second…
- Customer-Focused Drying Mode Adjustment["Press and hold the Dryness Level button for 5 seconds.","Dryer will beep and display CF for one…
- Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the Dry Level button for at…
- Damp Dry Test["Begin with an empty dryer and clean lint screen.","Set Timer to DAMP DRY.","Set Fabric…
- Diagnostic Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Clothes Dry…
- diagnostic_test_mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Clothes Dry…
- display_line_voltage["Enter diagnostic test mode.","Advance past all saved fault codes.","Press the Cycle Signal…
- Factory Test["Begin with an empty dryer and clean lint screen.","Door must be open.","Set Signal switch to…
- Install Diagnostics["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- Manual Diagnostic Test Mode1
- Manual Load Test["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Clothes Dry…
- manual_load_test["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Clothes Dry…
- Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Select any three buttons…
- Software Version Display["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
- User Interface/Control System Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana freezer models
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax