Model reference
Amana C7-C/P60116-32WC
Freezer
2 documents60 error codes15 service modes
Available documentation
Tech Tip
- Instruction Sheet - 854179912 pg
- Instruction Sheet - 397971412 pg
MyPros+ Max
Diagnose your Amana C7-C/P60116-32WC.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (60)
CodeMeaning
dLLid Lock FailuredULid Unlock FailureF-01Primary control failure in the machine control electronics.F-02Stuck button or user interface mismatchF-22Exhaust thermistor is open.F-23Exhaust thermistor has shorted.F-26Motor drive system failure.F-28Moisture sensor strip is openF-29Moisture sensor strip has shortedF-30Restricted air flow condition existsF-50No voltage detected at the water valve relay (steam model)F1Pressure Signal Out-of-RangeF1E1CCU errorF1E2MCU errorF2Keypad/User Interface FailureF2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F2E3Unsupported cycleF3E1Pressure system errorF3E2Temperature system errorF3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F40ATC Thermistor Open/ShortF41Motor RPS Thermistor Open/ShortF4E0Heater is not detectedF4E1No voltage detected at the heater relay; only appears in Diagnostic Test Mode.F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.View all 60 error codes
F50Motor StalledF51Motor RPS FailureF52Motor Stop FailureF53Motor Control OvertempF54Motor Control OvercurrentF5E1Door switch errorF5E2Door lock errorF5E3Door unlock errorF6E1Communication error between CCU and MCUF6E2Communication error UI to CCUF6E3Communication error CCU to UIF72Basket Re-engagement FailureF7E1Drive motor speed sensing error / washer overloadF7E2MCU overheat and/or motor overheatF8E0Steam inlet valve errorF8E1No water detected entering washer or pressure sensor trip not detectedF8E3Overflow conditionF9E1Long drainHCHot, Cold ReversedL2Low L2 voltage (less than 50V) detected at the CCU.LdLong DrainLFLong FilllidOpen/Close LidoLOverloadedPFPower failure occurred while the dryer was running.PoPump OutrLLoad detected during the washer cleaning cycle (remove load); saved as F0E1.SdSuds DetectionSudSuds detecteduLUnbalanced Load
Service modes (15)
- Automatic Diagnostic Test Mode["Ensure washer is in standby mode (plugged in with all indicators off, or with only Clothes Clean…
- Console and Indicators Diagnostic Test Mode["Plug in washer or reconnect power.","From Standby (Off) Mode, press and release the following…
- customer_focused_drying_mode_adjustment1
- Customer-Focused Dryness Level Adjustment1
- diagnostic_test_mode1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Done…
- display_line_voltageAfter all saved fault codes have been displayed in diagnostic test mode, press the End of Cycle…
- Fault/Error Code Display["Activate Service Diagnostic Mode first.","Press and release the 3rd button used to activate…
- Install Diagnostics1
- Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
- Manual Diagnostic Test Mode["Perform steps 1 and 2 of Automatic Diagnostic Test Mode entry (press/hold/release…
- manual_load_test1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Done…
- Quick Diagnostic Test["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- Service Diagnostic Mode["Ensure washer is in standby mode (plugged in with all indicators off).","Wait 30 seconds after…
- Software Version Display["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
- User Interface Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana freezer models
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax