Model reference
Amana C9-A/P60212-64WA
Freezer
45 error codes10 service modes
MyPros+ Max
Diagnose your Amana C9-A/P60212-64WA.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (45)
CodeMeaning
dLLid Lock FailuredULid Unlock FailureE3The heater cannot warm the water to the desired temperature within 90 minutes…E6NTC open circuit failure (only alarmed during on-line test).E7NTC short circuit failure (only alarmed during on-line test).F 1Pressure Signal Out-of-RangeF 2Keypad/User Interface FailureF 40ATC Thermistor Open/ShortF 41Motor RPS Thermistor Open/ShortF 42Heater in unknown stateF 43Heater is continuously ONF 44Heater cannot be turned ONF 50Motor StalledF 51Motor RPS FailureF 52Motor Stop FailureF 53Motor Control OvertempF 54Motor Control OvercurrentF 72Basket Re-engagement FailureF01Primary control failure in the machine control electronics.F02Stuck button or user interface mismatch; appears ONLY in diagnostic test mode.F1Pressure Signal Out-of-RangeF2Keypad/User Interface FailureF22Exhaust thermistor circuit is open.F23Exhaust thermistor has shorted.F26Motor drive system failure.F28Moisture sensor strip is open; appears ONLY in diagnostic test mode.F29Moisture sensor strip has shorted; appears ONLY in diagnostic test mode.F30Restricted air flow condition exists; appears ONLY in diagnostic test mode.F40ATC Thermistor Open/ShortF41Motor RPS Thermistor Open/ShortView all 45 error codes
F50No voltage detected at the water valve relay (steam model only); appears ONLY…F51Motor RPS FailureF52Motor Stop FailureF53Motor Control OvertempF54Motor Control OvercurrentF72Basket Re-engagement FailureHCHot, Cold ReversedLdLong DrainLFLong FilllidOpen/Close LidoLOverloadedPFPower failure occurred while the dryer was running.PoPump OutSdSuds DetectionuLUnbalanced Load
Service modes (10)
- Automatic Diagnostic Test Mode["Ensure washer is not currently running a cycle (in-progress screen should not be…
- Console and Indicators Diagnostic Test Mode["Ensure washer is not currently running a cycle and LCD is on.","Press Power/Cancel button and…
- Customer-Focused Drying Mode Adjustment["With dryer in standby mode, press and hold the Dryness Level button for 5 seconds.","Dryer will…
- Diagnostic Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Done…
- Manual Diagnostic Test Mode["Perform steps 1 and 2 of Activation of Automatic Diagnostic Test Mode (Sound and Display >…
- Manual Load Test["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Done…
- On-Line Check Mode (Service Diagnostics Cycle)1
- Pressure Transducer Calibration["Enter Manual Diagnostic Test Mode.","From the Component Activation screen, select the 'Pressure'…
- Saved Fault Codes["Enter Service Mode (Sound and Display > Service Mode > 5, 6, 5, 6 within 5 seconds >…
- Service Mode (Keypad/LED Test)Close the door, then within 60 seconds press RINSE ONLY and START/RESUME
Full entry steps, exit procedures, and test sequences are available in Max.