Error codes (68)

CodeMeaning
AFLow inlet air flow detected at install.dLLid Lock FailuredULid Unlock FailureF-01Primary control failure in the machine control electronics.F-02Stuck button or user interface mismatchF-22Exhaust thermistor is open.F-23Exhaust thermistor has shorted.F-26Motor drive system failure.F-28Moisture sensor strip is openF-29Moisture sensor strip has shortedF-30Restricted air flow condition existsF-50No voltage detected at the water valve relay (steam model)F:01Primary control failure.F:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Outlet thermistor is open.F:23Outlet thermistor has shorted.F:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).F:25Inlet thermistor has shorted (appears ONLY in Diagnostic Test Mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).F:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).F:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).F:31Low voltage condition (less than 30V) detected (appears ONLY in Diagnostic Test…F:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure (F:72 through F:78).F:73Console electronics failure (F:72 through F:78).F:74Console electronics failure (F:72 through F:78).
View all 68 error codes
F:75Console electronics failure (F:72 through F:78).F:76Console electronics failure (F:72 through F:78).F:77Console electronics failure (F:72 through F:78).F:78Console electronics failure (F:72 through F:78).F1Pressure Signal Out-of-RangeF1E1Indicates a CCU (Cycle Control Unit) problem.F2Keypad/User Interface FailureF2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F40ATC Thermistor Open/ShortF41Motor RPS Thermistor Open/ShortF4E1No voltage detected at the heater relay; only appears in Diagnostic Test Mode.F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F50Motor StalledF51Motor RPS FailureF52Motor Stop FailureF53Motor Control OvertempF54Motor Control OvercurrentF6E1Communication error from UI to CCU; communication between CCU and UI has not…F6E2Communication error from CCU to UI; communication between CCU and UI has not…F72Basket Re-engagement FailureHCHot, Cold ReversedL2Low line voltage (less than 30V) detected at installation.LdLong DrainLFLong FilllidOpen/Close LidoLOverloadedPFPower failure occurred while the dryer was running.PoPump OutSdSuds DetectionuLUnbalanced Load

Service modes (17)

  • Automatic Diagnostic Test Mode["Ensure washer is in standby mode (plugged in with all indicators off, or with only Clothes Clean…
  • Console and Indicators Diagnostic Test Mode["Plug in washer or reconnect power.","From Standby (Off) Mode, press and release the following…
  • customer_focused_drying_mode_adjustment1
  • Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)1
  • Customer-Focused Dryness Level Adjustment1
  • Diagnostic Test Mode1
  • diagnostic_test_mode1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Done…
  • display_line_voltageAfter all saved fault codes have been displayed in diagnostic test mode, press the End of Cycle…
  • Inlet Air Flow Test (Electric Models Only)After entering Diagnostic Test Mode and cycling through saved fault codes, press the Wrinkle Guard…
  • Install Diagnostics1
  • Line Voltage Display TestAfter entering Diagnostic Test Mode and cycling through saved fault codes, press the Cycle Signal…
  • Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
  • Manual Diagnostic Test Mode["Perform steps 1 and 2 of Automatic Diagnostic Test Mode entry (press/hold/release…
  • Manual Load Test1. Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Clothes…
  • manual_load_test1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Done…
  • Service Diagnostic Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Select any three buttons…
  • Software Version Display1

Full entry steps, exit procedures, and test sequences are available in Max.