Model reference
Amana C9-AG/P60318-48WG
Freezer
50 error codes20 service modes
MyPros+ Max
Diagnose your Amana C9-AG/P60318-48WG.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (50)
CodeMeaning
dLLid Lock FailuredULid Unlock FailureF 1Pressure Signal Out-of-RangeF 2Keypad/User Interface FailureF 40ATC Thermistor Open/ShortF 41Motor RPS Thermistor Open/ShortF 42Heater in unknown stateF 43Heater is continuously ONF 44Heater cannot be turned ONF 50Motor StalledF 51Motor RPS FailureF 52Motor Stop FailureF 53Motor Control OvertempF 54Motor Control OvercurrentF 72Basket Re-engagement FailureF1Pressure Signal Out-of-RangeF1E1No voltage detected at the heater relay; possible motor or heater failure or…F2Keypad/User Interface FailureF2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F3E1Exhaust thermistor is open or shorted (open if temp drops below 18°F / >50k…F3E2Moisture sensor strip 1 is open or shorted (only appears in service diagnostic…F3E3Inlet thermistor is open or shorted (open if temp drops below 18°F / >245k…F3E4Inlet thermistor has shorted; temperature above 391°F (<328 ohms).F3E5Second moisture sensor strip is open or shorted (Quad Sense models only; only…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F40ATC Thermistor Open/ShortF41Motor RPS Thermistor Open/ShortF4E1No voltage detected at the heater relay; only appears in Diagnostic Test Mode.F4E3Restricted/low air flow that may affect dryer performance.View all 50 error codes
F4E4Low L2 voltage (less than 50V) detected at the CCU.F50Motor StalledF51Motor RPS FailureF52Motor Stop FailureF53Motor Control OvertempF54Motor Control OvercurrentF6E1ACU and HMI have not communicated for a specified amount of time.F6E2WiFi Module has not responded for a specified amount of time.F72Basket Re-engagement FailureFCE1WiFi Module communications lost.HCHot, Cold ReversedL2Low L2 voltage (less than 50V) detected at the CCU.LdLong DrainLFLong FilllidOpen/Close LidoLOverloadedPFPower failure occurred while the dryer was running.PoPump OutSdSuds DetectionuLUnbalanced Load
Service modes (20)
- Automatic Diagnostic Test Mode["Ensure washer is not currently running a cycle (in-progress screen should not be…
- automatic_diagnostic1
- Component Activation / Quick Service Cycle (LCD in Door Models)["Enter Service Diagnostic Mode (LCD in Door) first.","From the DIAGNOSTICS HOME screen, scroll…
- Console and Indicators Diagnostic Test Mode["Ensure washer is not currently running a cycle and LCD is on.","Press the Power/Cancel button and…
- console_and_indicators_diagnostic1. Plug in washer or reconnect power. 2. From Standby (Off) Mode, press and release the following…
- Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS LEVEL button…
- Install Diagnostics["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- Key Activation & Encoder Test (Console Models)["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
- Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds: Press…
- Manual Diagnostic Test Mode["Read and perform steps 1 and 2 of Activation of Automatic Diagnostic Test Mode (enter Service…
- manual_diagnostic1
- Pressure Transducer Calibration["Enter Manual Diagnostic Test Mode.","From the Component Activation screen, select the 'Pressure'…
- Saved Fault Codes["Enter Service Mode (Sound and Display > Service Mode > 5, 6, 5, 6 > Enter).","From the Diagnostic…
- Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Select any three buttons…
- Service Diagnostic Mode (Console Models)["Ensure the dryer is in standby mode (plugged in with all indicators off).","Select any three (3)…
- Service Diagnostic Mode (LCD in Door Models)["Ensure the dryer is in standby mode (plugged in with all indicators off).","Open and close the…
- Service Test Mode (Console Models)["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- Software Version Display["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
- Software Version Display (Console Models)["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
- User Interface Test["First activate the Service Diagnostic Mode.","Press and release the 1st button used to activate…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana freezer models
75,000+ service documents · 20,000+ error codes · 100+ brands