Model reference
Amana GC105DF-3/P96331-24F
Furnace
10 documents32 error codes11 service modes
Available documentation
Tech Sheet
- Tech Sheet W10156034 110 6808270012 pg
- Tech Sheet - W10156735A16 pg
- Tech Sheet W1030148212 pg
Installation Guide
- Installation Instructions34 pg
- Installation Instructions7 pg
- Installation Instructions21 pg
- Installation Instructions11 pg
- Instrucciones de instalacion56 pg
- Installation Instructions21 pg
- Installation Instructions5 pg
MyPros+ Max
Diagnose your Amana GC105DF-3/P96331-24F.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (32)
CodeMeaning
AFRestricted air flow condition exists.F:01Primary control failure.F:02Stuck button or user interface mismatch (only appears in diagnostic test mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Exhaust thermistor is open.F:23Exhaust thermistor has shorted.F:24Inlet thermistor is open (only appears in diagnostic test mode).F:25Inlet thermistor is shorted (only appears in diagnostic test mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (only appears in diagnostic test mode).F:29Moisture sensor strip has shorted (only appears in diagnostic test mode).F:30Restricted air flow condition exists (only appears in diagnostic test mode).F:31Low voltage condition (less than 30V) has been detected (appears ONLY in…F:40Communication between the machine control and motor control is lost.F:41Blower motor failure.F:42Motor control detects a voltage less than 90 VAC (undervoltage failure).F:43Motor control detects a low voltage condition (undervoltage warning); dryer…F:44Motor control electronics failure.F:45Motor control electronics speed sensor failure.F:46Motor control detects an over-current or over-torque condition.F:50No voltage detected at the water valve relay (steam model only, only appears in…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure.F:73Console electronics failure.F:74Console electronics failure.F:75Console electronics failure.F:76Console electronics failure.F:77Console electronics failure.F:78Console electronics failure.Service modes (11)
- Adjusting Customer-Focused Drying Modes["Press and hold the Dryness Level button for 5 seconds.","Dryer will beep and display CF for 1…
- Automatic Function TestWith door latched, press key pads in the following sequence within 10 seconds
- Customer-Focused Drying Mode Adjustment["With the dryer in standby mode, press and hold the Dryness Level button for 5 seconds.","The…
- Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)["In Standby mode (dryer plugged in but not powered up), press and hold the Dryness Level button…
- Diagnostic Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Done…
- Displaying Inlet Air Flow["Enter diagnostic test mode and advance past all saved fault codes.","Press the Wrinkle Guard…
- Displaying Line Voltage["Enter diagnostic test mode and advance past all saved fault codes.","Press the Cycle Signal…
- Dryness Level Adjust (CF Mode)1
- Factory Default Reset1
- Manual Function TestWith door latched, press key pads in the following sequence within 10 seconds
- Manual Load Test["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Done…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana furnace models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass