mypros+
Model reference

Amana GC105DF-3/P96331-24F

Furnace

10 documents32 error codes11 service modes

Available documentation

Tech Sheet

  • Tech Sheet W10156034 110 6808270012 pg
    Covers this model
  • Tech Sheet - W10156735A16 pg
    Covers this model
  • Tech Sheet W1030148212 pg
    Covers this model

Installation Guide

  • Installation Instructions34 pg
    Covers this model
  • Installation Instructions7 pg
    Covers this model
  • Installation Instructions21 pg
    Covers this model
  • Installation Instructions11 pg
    Covers this model
  • Instrucciones de instalacion56 pg
    Covers this model
  • Installation Instructions21 pg
    Covers this model
  • Installation Instructions5 pg
    Covers this model
MyPros+ Max

Diagnose your Amana GC105DF-3/P96331-24F.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (32)

CodeMeaning
AFRestricted air flow condition exists.F:01Primary control failure.F:02Stuck button or user interface mismatch (only appears in diagnostic test mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Exhaust thermistor is open.F:23Exhaust thermistor has shorted.F:24Inlet thermistor is open (only appears in diagnostic test mode).F:25Inlet thermistor is shorted (only appears in diagnostic test mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (only appears in diagnostic test mode).F:29Moisture sensor strip has shorted (only appears in diagnostic test mode).F:30Restricted air flow condition exists (only appears in diagnostic test mode).F:31Low voltage condition (less than 30V) has been detected (appears ONLY in…F:40Communication between the machine control and motor control is lost.F:41Blower motor failure.F:42Motor control detects a voltage less than 90 VAC (undervoltage failure).F:43Motor control detects a low voltage condition (undervoltage warning); dryer…F:44Motor control electronics failure.F:45Motor control electronics speed sensor failure.F:46Motor control detects an over-current or over-torque condition.F:50No voltage detected at the water valve relay (steam model only, only appears in…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure.F:73Console electronics failure.F:74Console electronics failure.F:75Console electronics failure.F:76Console electronics failure.F:77Console electronics failure.F:78Console electronics failure.
View all 32 error codes

Service modes (11)

  • Adjusting Customer-Focused Drying Modes["Press and hold the Dryness Level button for 5 seconds.","Dryer will beep and display CF for 1…
  • Automatic Function TestWith door latched, press key pads in the following sequence within 10 seconds
  • Customer-Focused Drying Mode Adjustment["With the dryer in standby mode, press and hold the Dryness Level button for 5 seconds.","The…
  • Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)["In Standby mode (dryer plugged in but not powered up), press and hold the Dryness Level button…
  • Diagnostic Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Done…
  • Displaying Inlet Air Flow["Enter diagnostic test mode and advance past all saved fault codes.","Press the Wrinkle Guard…
  • Displaying Line Voltage["Enter diagnostic test mode and advance past all saved fault codes.","Press the Cycle Signal…
  • Dryness Level Adjust (CF Mode)1
  • Factory Default Reset1
  • Manual Function TestWith door latched, press key pads in the following sequence within 10 seconds
  • Manual Load Test["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Done…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass