9 documents54 error codes15 service modes
Available documentation
Tech Sheet
- Tech Sheet - RT52800077 pg
- techsheet-de68-03117k.pdf1 pg
- Tech Sheet - W11503313 - Rev A2 pg
- Tech Sheet - RT532001214 pg
Service Manual
- Service Manual - SAM002823 pg
- Service Manual - SAM003023 pg
Installation Guide
- Installation Instructions22 pg
- Installation Instructions35 pg
- Installation Instructions33 pg
MyPros+ Max
Diagnose your Amana GH-105-3.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (54)
CodeMeaning
:Power failure indication; the colon is displayed on the screen after a power…afLow inlet air flow condition detected at installation (Amana models only).DoorDoor Interlock Primary Switch error.Err1Failed H.VErr2Failed H.VErr3Failed H.VErr4Failed H.VErr5Failed Touch Panel (touch panel pressed for more than 30 seconds triggers this…Err6Failed H.VErr7Error with RTD circuiterror1Shorted sensor circuit.error2Open sensor circuit.error3On the cooling mode, sensor's Vout was not less than 4.7V within 3 minutes.error4On the way to sensing, the door was opened.f:01Primary control failure.f:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).f:20Heater failuref:22Outlet thermistor is open.f:23Outlet thermistor has shorted.f:24Inlet thermistor is open (Amana models only, appears ONLY in Diagnostic Test…f:25Inlet thermistor is shorted (Amana models only, appears ONLY in Diagnostic Test…f:26Motor drive system failure.f:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).f:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).f:30Restricted air flow condition exists (Amana models only, appears ONLY in…f:31L2 line voltage errorf:50Water valve failuref:70No communication between the machine control and the console electronics.f:71No communication between the machine control and the console electronics.f:72Console electronics failure (F:72 through F:78).View all 54 error codes
f:73Console electronics failure (F:72 through F:78).f:74Console electronics failure (F:72 through F:78).f:75Console electronics failure (F:72 through F:78).f:76Console electronics failure (F:72 through F:78).f:77Console electronics failure (F:72 through F:78).f:78Console electronics failure (F:72 through F:78).F1E4Microwave ACU PCBA failure.F2Touch panel failure.F2E1Stuck key failure on touch panel.F3E0Main oven sensor open or shorted.F3E2Warming drawer sensor open or shorted.F4E1Cavity temperature sensor failure.F4E4Humidity sensor error.F4E9Smart pop error.F5E0Door and switches do not agree (Clean modeF5E1Door latch not operating (Clean modeF6MW relay failure (Relay 4903 on PCBA); relay contact may have welded closed.F6E1Over temperature during cook operation.F6E3Over temperature in warming drawer.F8E5Exhaust air template detection failure (HF NTC thermistor issue).F9E0Mis-wired house or range electrical connection.HOTOven overtemperature conditionl2Low line voltage (less than 30V) detected at installation.pfPower failure occurred while the dryer was running.
Service modes (15)
- Auto TestFollow steps 1 through 4 to run Auto Test
- Automatic Function TestWith door latched, press key pads in the following sequence within 10 seconds
- Convection Temperature Calibration["Door must be closed.","Press HIDDEN PAD.","Press pads 1, 3, 5, 7, 9.","Press '0' pad to view…
- Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)1
- Diagnostic Test Mode1. Dryer must be in standby mode (plugged in with all indicators off, or with only Done/Dry/Clothes…
- Diagnostics Mode["Plug in microwave oven or reconnect power.","Press CANCEL button to reach standby (display shows…
- Displaying Inlet Air Flow Diagnostic (Amana Electric Models Only)["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
- Displaying Line Voltage Diagnostic["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
- Inlet Air Flow Diagnostic (Amana Electric Models Only)After entering the Diagnostic Test Mode and cycling through saved fault codes, press the Wrinkle…
- Line Voltage DiagnosticAfter entering the Diagnostic Test Mode and cycling through saved fault codes, press the Cycle…
- Manual Function TestWith door latched, press key pads in the following sequence within 10 seconds
- Manual Load Test1. Dryer must be in standby mode. 2. Select any one button except Pause/Cancel and Controls…
- Power Test (Traditional Test Method)["Place one rack in oven using lowest rack position.","Fill plastic container to bottom of 1000 ml…
- Service Test Mode["Oven must be in STANDBY mode with door closed.","Press Hidden Pad.","Press pads 1, 3, 5, 7…
- Touch Panel and PCBA Self-Diagnostic Test Mode["Press and hold the CANCEL/OFF button while opening the door.","While still holding the CANCEL/OFF…