5 documents13 error codes17 service modes
Available documentation
Service Manual
- Service Manual - W10670270A76 pg
Service Flash
- UD-41 Update Book Service Update First Half 201168 pg
Installation Guide
- Installation Instructions32 pg
- Installation Instructions5 pg
- Installation Instructions32 pg
MyPros+ Max
Diagnose your Amana GH-80DE-3/P96294-6F.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (13)
CodeMeaning
:Steady colon indicates a power failure has occurred.Err7Key errorF1E1No voltage detected at the heater relay; possible motor or heater failure or…F2Touch panel failure.F3E1Exhaust thermistor is open or shorted (open if temp drops below 18°F / >50k…F3E2Moisture sensor strip 1 is open or shorted (only appears in service diagnostic…F3E3Inlet thermistor is open or shorted (open if temp drops below 18°F / >245k…F3E5Second moisture sensor strip is open or shorted (Quad Sense models only; only…F6MW relay failure (Relay 4903 on PCBA); relay contact may have welded closed.F6E1ACU and HMI have not communicated for a specified amount of time.F6E2WiFi Module has not responded for a specified amount of time.FCE1WiFi Module communications lost.PFPower failure indication; blinks in the display after a power outage longer…Service modes (17)
- Automatic Function TestWith door latched, press key pads in the following sequence within 10 seconds
- automatic_diagnostic["Turn the product on.","Within 20 seconds of Power On, press and hold the Clean button first, then…
- clean_mode["Press ON/OFF button to stop ice production.","Wait 10 minutes for ice to fall into storage bin
- Component Activation / Quick Service Cycle (LCD in Door Models)["Enter Service Diagnostic Mode (LCD in Door) first.","From the DIAGNOSTICS HOME screen, scroll…
- diagnostic1
- Key Activation & Encoder Test (Console Models)["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
- Manual Function TestWith door latched, press key pads in the following sequence within 10 seconds
- manual_diagnostic["Turn the product on.","Within 20 seconds of Power On, press and hold the Clean button first, then…
- Self-Diagnostic / Test Mode["1
- Self-Diagnostic Test Mode["1
- Service Diagnostic Mode (Console Models)["Ensure the dryer is in standby mode (plugged in with all indicators off).","Select any three (3)…
- Service Diagnostic Mode (LCD in Door Models)["Ensure the dryer is in standby mode (plugged in with all indicators off).","Open and close the…
- Service Mode Diagnostics["Make sure that the unit is not in the 'lockout' mode (the lockout LED will be off).","Press and…
- Service Test Mode (Console Models)["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- Showroom Floor ModeReferenced as a feature of the Fast Fill Dispenser System but no entry procedure is detailed in…
- Software Version Display (Console Models)["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
- Touch Panel and PCBA Self-Diagnostic Test Mode["Press and hold the CANCEL/OFF button while opening the door.","While still holding the CANCEL/OFF…
Full entry steps, exit procedures, and test sequences are available in Max.