Amana VHC-2/P72908-2M

Hood

5 documents50 error codes12 service modes

Available documentation

Tech Sheet

  • Tech Sheet - W10050530 - Rev A12 pg
    Covers this model
  • Whirlpool Dryer 110 61082000 Tech Sheet 39787158 pg
    Covers this model
  • wiring-sheet-W10875373.pdf31 pg
    Covers this model

Tech Tip

  • Instruction Sheet - 39795428 pg
    Covers this model
  • Instruction Sheet - 3977700 - Rev A8 pg
    Covers this model
MyPros+ Max

Diagnose your Amana VHC-2/P72908-2M.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (50)

CodeMeaning
1Thermistor short sensed10No wet clothes2Thermistor open sensed3Door circuit failure4Possible motor transistor error8Stuck keyAFLow inlet air flow detected at install.dCDoor circuit failuredoDoor openE1Thermistor is open (open circuit detected in the thermistor).E2Thermistor has shorted (short circuit detected in the thermistor).E3User interface (keyswitch) or software mismatch between the control…E6NTC open circuit failure (only alarmed during on-line test).E7NTC short circuit failure (only alarmed during on-line test).F:01Primary control failure.F:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Outlet thermistor is open.F:23Outlet thermistor has shorted.F:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).F:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).F:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).F:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).F:31Low voltage condition (less than 30 V) detected (appears ONLY in Diagnostic…F:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure.
View all 50 error codes

Service modes (12)

  • ADC Test Mode - First Method["Turn the thermostat off for 15 seconds","Turn the thermostat on for 5 seconds","Turn the…
  • ADC Test Mode - Second Method["Disconnect the refrigerator/freezer from the wall outlet for at least 30 seconds","Turn the…
  • Clear Diagnostic CodesWhile viewing the diagnostic code list in Service Mode, press the Sensor Dry Level and Time keypads…
  • Customer-Focused Drying Mode Adjustment["With dryer in standby mode, press and hold the Dryness Level button for 5 seconds.","Dryer will…
  • Diagnostic Code Display1
  • Diagnostic Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Done…
  • LED/Switch Check1. Enter Service Mode first. 2. Press Chime and Wrinkle Prevent keys simultaneously for 3 seconds…
  • Manual Load Test["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Done…
  • On-Line Check Mode (Service Diagnostics Cycle)1
  • Service Mode1
  • Service Mode (Keypad/LED Test)Close the door, then within 60 seconds press RINSE ONLY and START/RESUME
  • System Check Mode1. Enter Service Mode first. 2. Press Time and Wrinkle Prevent keys simultaneously for 3 seconds…

Full entry steps, exit procedures, and test sequences are available in Max.