Error codes (31)
CodeMeaning
F/01EEPROM communication error between the Central Control Unit (CCU) and the…F/11Serial communication error between the Central Control Unit (CCU) and the Motor…F/20No water detected entering machine or pressure switch trip not detected after 6…F/21Long drainF/22Door lock errorF/23Heater failureF/24Water temperature sensor (NTC) errorF/25Drive motor tachometer errorF/26Door switch errorF/27Overflow conditionF/28Dispenser system errorF/29Door unlock errorF/30Pump drive system errorF/31MCU failureF/32Pump drive system errorF/33Pump drive errorF/34Load detected inside drum during the Cleaning Washer cycle (detected by…F/35Main relays errorF/36Motor Control Unit errorF2 E0Keypad (keyboard) faultF2 E1Keypad (keyboard) faultF3 E2Warming drawer sensor shorted or open circuit.F4 E1Microwave oven convection thermistor fault.F4 E2Microwave oven internal temperature sensor fault.F4 E4Microwave oven humidity sensor fault.F5No feature identified for microwaveF5 E0Door and latch switch do not agreeF5 E1Door latch not operatingF6 E5No cavity size commandrLLoad detected inside drum during the Cleaning Washer cycle (detected by weight).View all 31 error codes
Service modes (10)
- Cavity size programming["Disconnect oven or interrupt power","Wait 10 seconds, reconnect power","Enter diagnostic mode
- Clear last fault code["Disconnect oven or interrupt power","Wait 10 seconds, reconnect power","Enter diagnostic mode
- Diagnostic component activation["Enter diagnostic mode (OFF, OFF, START)","Press Bake to activate bake relay","Press Broil once…
- Diagnostic mode["Press OFF","Press OFF","Press START","If the appliance does not enter diagnostic mode, repeat the…
- Fahrenheit/Celsius selection["Press OPTIONS then 1"]
- Manual Diagnostic Test["Ensure washer is empty and control is in the OFF state.","Follow the manual diagnostic test entry…
- Quick Entry Diagnostic Test (Bypass Service History)1
- Quick Entry Diagnostic Test (bypassing Service History Mode)["Ensure washer drum is empty.","Close the door.","Press POWER.","Select the CLEAN WASHER…
- Service History Mode & Diagnostic Test (Universal Entry)["Ensure washer is empty and control is in the OFF state.","Close the door.","Select any one key…
- Temperature calibration adjustment["Press OPTIONS then 6","For double oven only, select desired oven (upper or lower)","Press 3 to…