mypros+
Model reference

Amana LC10VP000

Microwave

8 documents45 error codes15 service modes

Available documentation

Tech Sheet

  • Tech Sheet W11398327 RevA4 pg
    Covers this model
  • Tech Sheet W11365092 RevA4 pg
    Covers this model
  • tech sheet w11297783 revb20 pg
    Covers this model
  • Wiring Sheet - W11336175 - Rev A2 pg
    Covers this model
  • Tech Sheet16 pg
    Covers this model
  • Tech Sheet - W10419696 - Rev A28 pg
    Covers this model
  • FICHE TECHNIQUE - 8304553 - Rev B16 pg
    Covers this model

Installation Guide

  • Installation Instructions8 pg
    Covers this model
MyPros+ Max

Diagnose your Amana LC10VP000.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (45)

CodeMeaning
Enter clockPower failure has occurred; 'Enter clock' flashes on display.F0E0No fault detected (GOOD)F1.E1Relay Control Board defective.F1E0Internal board failure on the control.F1E1A/D (Analog to Digital) error(s) in the control board.F1E2Shorted keypad detected.F1E4MW Relay failure (Relay 4903 on ACU).F2.H1Hood/light switch stuck.F2.H2Hood/light switch error.F2.Q1User interface board (UIB) is not reading keypad inputs.F2E1Touch panel failure.F2E2User Interface Software Error 1F2E3User Interface Software Error 2F3.H1Humidity sensor failure.F3.T1UIB (user interface board) thermistor failure.F3.T4Magnetron thermistor failure.F3E0Oven sensor opened, oven sensor shorted, bake/broil range over temperature, or…F3E1Exhaust thermistor is open; temperature drops below 18°F (> 50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (< 500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (> 245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (< 328 ohms).F3E5Inlet and exhaust thermistor are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in service diagnostic…F4E2Internal temperature sensor fault (microwave oven sensor).F4E3Restricted air flow that may affect dryer performance.F4E4Humidity sensor error.F5E0Door and latch switch do not agree.F5E1Door latch not operating.
View all 45 error codes

Service modes (15)

  • Diagnostic / Self-Diagnostic Test Mode["Plug in microwave oven or reconnect power.","In idle mode, close the door, turn off hood light…
  • Diagnostic / Test Mode["Plug in microwave oven or reconnect power.","Press Cancel button to enter Standby mode (colon ':'…
  • Diagnostic modePress OFF, OFF, START to enter diagnostic mode and check fault codes.
  • Diagnostics / Test Mode["Plug in microwave oven or reconnect power.","Press CANCEL to enter Standby mode (colon ':'…
  • Diagnostics ModePress CANCEL > CANCEL > START within a 5-second period.
  • Diagnostics mode (for failure code verification)["Press CANCEL
  • Diagnostics Test Mode (Relay Checks)While in Diagnostics mode, press the following keypads to test individual control relays
  • Extended diagnostic mode (relay activation and testing)1
  • Quick Diagnostic TestFrom Service Diagnostics, navigate to Error Diagnostic > Quick Diagnostic Test
  • Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
  • Temperature AdjustmentStep 1
  • Touch Panel and ACU Diagnostic Test["Plug in microwave oven or reconnect power.","In idle mode, close the door, turn off hood light…
  • Touch Panel Test Mode["1
  • UI Component TestFrom Service Diagnostics, navigate to Component Activation > UI Component Test
  • User interface programming (after UI replacement)1

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass