Model reference
Amana RC-8/P75260-3M
Microwave
1 document47 error codes20 service modes
Available documentation
Tech Sheet
- Tech Sheet W11523158 Rev B2 pg
MyPros+ Max
Diagnose your Amana RC-8/P75260-3M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (47)
CodeMeaning
afLow inlet air flow condition detected at installation.f:01Primary control failure.f:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).f:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).f:22Outlet thermistor is open.f:23Outlet thermistor has shorted.f:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).f:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).f:26Motor drive system failure.f:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).f:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).f:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).f:31L2 line voltage errorf:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…f:70No communication between machine control and console electronics.f:71No communication between machine control and console electronics.f:72Console electronics failure (F:72 through F:78).f:73Console electronics failure (F:72 through F:78).f:74Console electronics failure (F:72 through F:78).f:75Console electronics failure (F:72 through F:78).f:76Console electronics failure (F:72 through F:78).f:77Console electronics failure (F:72 through F:78).f:78Console electronics failure (F:72 through F:78).F1E0Internal board failure.F1E1Primary control failure.F1E2A/D error(s).F2E1Stuck button or user interface mismatch (keypad/user interface failure)F2E2UI software error; UI cannot read EEPROM software.F3E0Oven sensor opened, oven sensor shorted, bake/broil range over temperature, or…F3E1Exhaust thermistor is open.View all 47 error codes
F3E2Exhaust thermistor has shorted.F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms)F3E4Inlet thermistor is shorted; temperature above 760°F (<20 ohms)F3E5Both inlet and exhaust thermistors are open; will occur if P14 connector is not…F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shortedF4E1No voltage detected at the heater relayF4E3Restricted air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 30V) detected at the CCU.F5E0Door and switches do not agree (Clean mode) (on some models).F5E1Door latch not operating (Clean mode) (on some models).F6E1Oven over temperature when heating.F6E2Communication error from CCU to UI; communication has not been detected.F8E1No voltage detected at the water valve relay (steam models only)F9E0Miswired house or miswired range.l2Low line voltage (less than 30V) detected at installation.pfPower failure occurred while the dryer was running.
Service modes (20)
- Component ActivationFrom Service Diagnostics Diagnostics Home screen, select 'Component Activation'
- Customer-Focused Drying Mode Adjustment["Ensure dryer is in standby mode.","Press and hold the TEMP button for more than 6…
- Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)1
- Customer-Focused Drying Modes Adjustment["Activate the Diagnostic Test Mode.","Select the Component Activation option.","Select…
- Diagnostic Test Mode["Ensure the dryer is not currently running a cycle (in-progress screen should not be…
- Diagnostics modePress CANCEL > CANCEL > START within a 5 second period.
- Displaying Inlet Air Flow Diagnostic (Amana Electric Models Only)["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
- Displaying Line Voltage Diagnostic["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
- Inlet Air Flow Diagnostic (Amana Electric Models Only)After entering the Diagnostic Test Mode and cycling through saved fault codes, press the Wrinkle…
- Inlet Air Flow Test (Electric Models Only)["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Press the 'Air Flow'…
- Line Voltage DiagnosticAfter entering the Diagnostic Test Mode and cycling through saved fault codes, press the Cycle…
- Line Voltage Test["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Press the 'Line…
- Manual Diagnostic Test Mode["Perform steps 1 and 2 of Activating the Diagnostic Test Mode.","Select the Component Activation…
- Manual Diagnostic Test Mode (Component Activation)["Perform steps 1 and 2 of Activating the Diagnostic Test Mode.","Select the Component Activation…
- Manual Load Test["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Select individual…
- Quick Diagnostic TestFrom Service Diagnostics, navigate to Error Diagnostic, then select 'Quick Diagnostic Test'
- Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only DONE or…
- Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
- UI Component TestFrom Service Diagnostics, navigate to Component Activation, then select 'UI Component Test'
- User Interface/Control System Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana microwave models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass