8 documents53 error codes20 service modes

Available documentation

Tech Sheet

  • Tech Sheet - W10112989A12 pg
    Covers this model
  • FICHE TECHNIQUE - 8304553 - Rev B16 pg
    Covers this model
  • Tech Sheet - W10156041A16 pg
    Covers this model
  • Tech Sheet 8543719 110 2506650016 pg
    Covers this model

Service Manual

  • Instruction Sheet - 854371916 pg
    Covers this model

Tech Tip

  • Instruction Sheet - 39800578 pg
    Covers this model
  • Instruction Sheet - 397971412 pg
    Covers this model

Installation Guide

  • Installation Instructions7 pg
    Covers this model
MyPros+ Max

Diagnose your Amana RC7A-PB/P72651-1M.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (53)

CodeMeaning
3 beepsThermistor or wire harness is either shorted or open, detected when Push to…CAAverage current limit trip; a 2-second average current draw greater than 5.55…CECommunications error; breakdown in communication between the machine controller…CIInstantaneous current limit trip; a spike of 26 Amps was detected instantly at…E1Thermistor is open.E2Thermistor has shorted.E3User interface keyswitch or software mismatch between console electronics and…ErProcessor reset error; the control failed to save cycle information during a…F-01Primary control failure.F-02Stuck button or user interface mismatch (only appears in diagnostic test mode).F-22Exhaust thermistor is open.F-23Exhaust thermistor has shorted.F-26Motor drive system failure.F-28Moisture sensor strip is open (only appears in diagnostic test mode).F-29Moisture sensor strip has shorted (only appears in diagnostic test mode).F-50No voltage detected at the water valve relay (steam models only, only appears…F0E0No error(s) foundF1E0Internal failureF1E1Oven appliance manager failure (not applicable for lower oven on double oven…F2E0Keypad disconnected.F2E1Stuck key or shorted key.F2E2LED error on user interface.F3E0Upper oven temperature sensor open or shorted.F3E1Lower oven temperature sensor open or shorted.F3E2Warming drawer sensor shorted (oven not equipped with this feature).F3E3Meat probe sensor shorted.F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1Convection thermistor fault (microwave oven sensor).F4E2Internal temperature sensor fault (microwave oven sensor).
View all 53 error codes

Service modes (20)

  • Automatic Service DiagnosticsControl must be in Off state. Perform Key Dance within 5 seconds
  • Console Keypad and LED TestControl must be in Off state. Perform Key Dance within 5 seconds
  • Customer-Focused Drying Mode Adjustment1. Ensure dryer is in standby mode (plugged in with all indicators off, or only DONE indicator on)…
  • Diagnostic modePress OFF, OFF, START to enter diagnostic mode and check fault codes.
  • Diagnostic Test Mode["Ensure the dryer is in Standby Mode (plugged in and all indicators off).","Press the following…
  • diagnostic_test["Door must be open","Set Temperature switch to Air Fluff","Set End of Cycle Signal switch to…
  • Diagnostics ModePress any 3 keys 3 times within 8 seconds
  • Dryness Level Adjust (TEST #4a)["Enter the Diagnostic Test Mode (MORE TIME, LESS TIME, MORE TIME, LESS TIME within 5…
  • Dryness Level Adjust Mode["Enter the Diagnostic Test Mode (MORE TIME → LESS TIME → MORE TIME → LESS TIME within 5…
  • Extended diagnostic mode (relay activation and testing)1
  • Less Dry Test["Begin with a fully assembled, empty dryer with clean lint screen connected to a known good power…
  • less_dry_test["Begin with fully assembled, empty dryer with clean lint screen connected to known good power…
  • Manual DiagnosticsControl must be in Off state. Perform Key Dance within 5 seconds
  • Manual Load Test1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Dry…
  • Nutate and Recirculate TestControl must be in Off state. Perform Key Dance within 5 seconds
  • Service Diagnostic Mode1
  • Spin and Drain TestControl must be in Off state. Water should be present in the unit. Perform Key Dance within 5…
  • User interface programming (after UI replacement)1
  • User Interface/Control System Test1
  • Water Inlet and Dispenser Valve Operating PS TestControl must be in Off state. Perform Key Dance within 5 seconds

Full entry steps, exit procedures, and test sequences are available in Max.