Model reference

Amana RC7A-PB/P72651-1M

Microwave

2 documents42 error codes17 service modes

Available documentation

Tech Sheet

  • FICHE TECHNIQUE - 8304553 - Rev B16 pg
    Covers this model

Tech Tip

  • Instruction Sheet - 397971412 pg
    Covers this model
MyPros+ Max

Diagnose your Amana RC7A-PB/P72651-1M.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (42)

CodeMeaning
CAAverage current limit trip; a 2-second average current draw greater than 5.55…CECommunications error; breakdown in communication between the machine controller…CIInstantaneous current limit trip; a spike of 26 Amps was detected instantly at…E1Thermistor is open.E2Thermistor has shorted.E3User interface keyswitch or software mismatch between console electronics and…ErProcessor reset error; the control failed to save cycle information during a…F0E0No error(s) foundF1E0Internal failureF1E1Oven appliance manager failure (not applicable for lower oven on double oven…F2E0Keypad disconnected.F2E1Stuck key or shorted key.F2E2LED error on user interface.F3E1Lower oven temperature sensor open or shorted.F3E2Warming drawer sensor shorted (oven not equipped with this feature).F3E3Meat probe sensor shorted.F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1Convection thermistor fault (microwave oven sensor).F4E2Internal temperature sensor fault (microwave oven sensor).F4E4Humidity sensor fault (microwave oven sensor).F5E0Door and latch switch do not agree.F5E1Door latch not operating.F6E0Lost communications between user interface and appliance manager.F6E1Cook oven over temperature.F6E2Clean oven over temperature.F6E3Mini oven/warm drawer over temperature (not for built-in ovens).F6E4User interface/appliance manager mismatch.F6E5Cavity size is incorrect.F7E0Water level is not high enough or water did not boil fast enough.
View all 42 error codes

Service modes (17)

  • Automatic Service DiagnosticsControl must be in Off state. Perform Key Dance within 5 seconds
  • Console Keypad and LED TestControl must be in Off state. Perform Key Dance within 5 seconds
  • Customer-Focused Drying Mode Adjustment1. Ensure dryer is in standby mode (plugged in with all indicators off, or only DONE indicator on)…
  • Diagnostic modePress OFF, OFF, START to enter diagnostic mode and check fault codes.
  • Diagnostic Test Mode["Ensure the dryer is in Standby Mode (plugged in and all indicators off).","Press the following…
  • Diagnostics ModePress any 3 keys 3 times within 8 seconds
  • Dryness Level Adjust (TEST #4a)["Enter the Diagnostic Test Mode (MORE TIME, LESS TIME, MORE TIME, LESS TIME within 5…
  • Dryness Level Adjust Mode["Enter the Diagnostic Test Mode (MORE TIME → LESS TIME → MORE TIME → LESS TIME within 5…
  • Extended diagnostic mode (relay activation and testing)1
  • Less Dry Test["Begin with a fully assembled, empty dryer with clean lint screen connected to a known good power…
  • Manual DiagnosticsControl must be in Off state. Perform Key Dance within 5 seconds
  • Nutate and Recirculate TestControl must be in Off state. Perform Key Dance within 5 seconds
  • Service Diagnostic Mode1
  • Spin and Drain TestControl must be in Off state. Water should be present in the unit. Perform Key Dance within 5…
  • User interface programming (after UI replacement)1
  • User Interface/Control System Test1
  • Water Inlet and Dispenser Valve Operating PS TestControl must be in Off state. Perform Key Dance within 5 seconds

Full entry steps, exit procedures, and test sequences are available in Max.

76,000+ service documents · 19,000+ error codes · 100+ brands

Get Started