Model reference
Amana RL-3/P75589-4M
Microwave
10 documents67 error codes32 service modes
Available documentation
Service Manual
- Service Manual - RS532001441 pg
- Service Manual - RS210000187 pg
- servicemanual w10881701 l 9164 pg
Tech Sheet
- YGEW9877JQ1 Tech Sheet 853203812 pg
- Wiring sheet - W11460669 - Rev A2 pg
- Tech Sheet - W10340328 - Rev A64 pg
- tech sheet w11421232 reva60 pg
Installation Guide
- Instruction Sheet4 pg
- Installation Instructions33 pg
- Installation Instructions30 pg
MyPros+ Max
Diagnose your Amana RL-3/P75589-4M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (67)
CodeMeaning
afLow inlet air flow condition detected at installation.CSCurrent Sensef:01Primary control failure.f:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).f:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).f:22Outlet thermistor is open.f:23Outlet thermistor has shorted.f:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).f:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).f:26Motor drive system failure.f:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).f:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).f:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).f:31L2 line voltage errorf:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…f:70No communication between machine control and console electronics.f:71No communication between machine control and console electronics.f:72Console electronics failure (F:72 through F:78).f:73Console electronics failure (F:72 through F:78).f:74Console electronics failure (F:72 through F:78).f:75Console electronics failure (F:72 through F:78).f:76Console electronics failure (F:72 through F:78).f:77Console electronics failure (F:72 through F:78).f:78Console electronics failure (F:72 through F:78).f1 e1Primary control failure.F1E1Primary control failure.F1E3Incorrect controller installed (electric models only); ACU and/or UI part…F1E5ACU parameter file missing.f2 e1Stuck button or user interface mismatch (only appears in service diagnostic…F2E1Stuck button or user interface mismatch (keypad/user interface failure)View all 67 error codes
F2E3User Interface and ACU model ID parameter mismatch caused by replacement with…F2E4UI software errorF2E5UI software errorf3 e1Exhaust thermistor is open.f3 e2Exhaust thermistor has shorted.f3 e6Moisture sensor strip is open (only appears in service diagnostic mode).f3 e7Moisture sensor strip has shorted (only appears in service diagnostic mode).F3E1Exhaust thermistor is open.F3E2Exhaust thermistor has shorted.F3E3Inlet thermistor is open or shorted; open if temperature drops below 18°F…F3E5Second moisture sensor strip is open or shorted (only Quad Sense models)F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shortedf4 e4Low line voltage detected.F4E1No voltage detected at heater relay 1, indicating a heater failure or connector…F4E2No voltage detected at heater relay 2 (electric models only), indicating a…F4E3Low airflow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50 V) detected at the CCU (electric models only).F4E5Temperature threshold of the dryer has been exceeded, usually indicating poor…F6E1HMI/ACU Communication Error between the Human Machine Interface and the…F6E2HMI/ACU Communication Error between the Human Machine Interface and the…F6E3Communication errorf8 e1No voltage detected at the water valve relay (steam models only)F8E1No voltage detected at the water valve relay (steam models only)FCE1WIFI Module Communications LostFHHigh current sense condition detected.FLLow current sense condition detected.HIHigh line voltage detectedHOTMagnetron overheating condition detected; blower motor should be operating when…l2Low line voltage (less than 30V) detected at installation.LOLow line voltage detectedPCE1Checksum errorPCE5Communication failure between high voltage board, low voltage board, and/or…PCE6Communication failure between high voltage board, low voltage board, and/or…pfPower failure occurred while the dryer was running.PLPower level error condition.S1Watchdog circuit verifies touch panel entry; indicates a shorted touch panel.
Service modes (32)
- Adjusting Customer-Focused Dryness Level["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS button for…
- Auto Cook Diagnostic Test (Quick Test)["For MVH120, 220, and 320 models
- Customer-Focused Drying Mode Adjustment["Ensure dryer is in standby mode.","Press and hold the TEMP button for more than 6…
- Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)1
- Customer-Focused Drying Modes Adjustment["Activate the Diagnostic Test Mode.","Select the Component Activation option.","Select…
- Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS button for…
- diagnostic["Set door to open position","Set temperature switch to Air Only","Set End of Cycle Signal switch…
- Diagnostic Test Mode["Ensure the dryer is not currently running a cycle (in-progress screen should not be…
- Displaying Inlet Air Flow Diagnostic (Amana Electric Models Only)["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
- Displaying Line Voltage Diagnostic["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
- Door Cycles and Magnetron Hours["Enter Service Test Mode.","Press TIME ENTRY pad once for door cycles (counter advances one number…
- Fault Code Display / Clear["1. Activate Service Diagnostic Mode first.","2. Press and release the 3rd button used to activate…
- Fault Code Display and ClearingFrom Service Diagnostic Mode, press and release the 3rd button to advance through saved fault codes
- H.V. System Test["Enter Service Test Mode.","Press pad 1 to activate H.V
- Inlet Air Flow Diagnostic (Amana Electric Models Only)After entering the Diagnostic Test Mode and cycling through saved fault codes, press the Wrinkle…
- Inlet Air Flow Test (Electric Models Only)["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Press the 'Air Flow'…
- Key Activation & Encoder Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
- Key Activation and Encoder TestFrom Service Diagnostic Mode, press and release the 1st button used to activate Service Diagnostic…
- less_dry_test["Begin with a fully assembled, empty dryer with clean lint screen connected to a known good power…
- Line Voltage DiagnosticAfter entering the Diagnostic Test Mode and cycling through saved fault codes, press the Cycle…
- Line Voltage Test["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Press the 'Line…
- Manual Diagnostic Test Mode["Perform steps 1 and 2 of Activating the Diagnostic Test Mode.","Select the Component Activation…
- Manual Diagnostic Test Mode (Component Activation)["Perform steps 1 and 2 of Activating the Diagnostic Test Mode.","Select the Component Activation…
- Manual Load Test["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Select individual…
- Power Performance Test["Measure line voltage (loaded)
- Programming Mode (Changing User Options)["Open oven door.","Press pad 1 for five seconds until signal sounds
- Sensor Detection Test (MVH120, 220, 320)["Place approximately 1/4 cup of water in the right front corner of oven cavity","Press AUTO COOK…
- Sensor Detection Test (MVH130, 230, 330)["Place approximately 1/4 cup of water in the right front corner of oven cavity","Press FRESH…
- Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only DONE or…
- Service Test Mode["Open door and place 1000 ml water load in oven.","Within 15 seconds, perform the following…
- Software Version Display["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate the…
- User Interface/Control System Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana microwave models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass