Model reference
Amana RR-10A/P73560-2M
Microwave
5 documents87 error codes26 service modes
Available documentation
Tech Sheet
- wiring diagram-a.pdf1 pg
- techsheet-w10420006-reva_W1042000656 pg
- Tech Sheet - W10393006 - Rev B52 pg
Tech Tip
- Instruction Sheet - 39791166 pg
Other
- tech-sheet-W10865055-RevA60 pg
MyPros+ Max
Diagnose your Amana RR-10A/P73560-2M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (87)
CodeMeaning
AFRestricted/low air flow detected that may affect dryer performance.F0 E7Control board recognized line voltage below 90 VAC.F0-E0Default code indicating no fault present.F01EEPROM errorF06Main relays errorF1 E1ACU (Appliance Control Unit) fault.F1 E7ACU voltage input fault.F1-E0Electronic control module failure.F1-E1Electronic control module failure.F1-E2Electronic control module failure.F1-E3Electronic control module failure.F1-E4Electronic control module failure.F11Steamer defectF1E1Indicates a Cycle Control Unit (CCU) problem.F1E3Incorrect controller installed (electric models only); ACU and/or UI part…F1E5ACU parameter file missing; parameter memory invalid.F2 E1Lower dryer keypad is sensed pressed for 60 seconds (stuck key).F2 E2Upper dryer keypad is sensed pressed for 60 seconds (stuck key).F2-E0Keypad not connected.F2-E1Keypad not connected.F2-E2Prolonged key press or short circuit on keypad.F20No water detected entering machine or pressure switch trip not detectedF21Long drainF22Door lock errorF24Water temperature sensor (NTC) errorF25Drive motor tachometer errorF26Door switch errorF27Overflow conditionF28Serial communication errorF29Door unlock errorView all 87 error codes
F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F2E2User Interface Software ErrorF2E4UI software errorF2E5UI software errorF3-E0Lower temperature sensor open circuit.F3-E1Lower temperature sensor short circuit.F3-E2Microwave temperature sensor open circuit.F3-E3Microwave temperature sensor short circuit.F30Dispenser system errorF31Motor Control Unit (MCU) failureF32Pressure switch failureF34Unload indicationF35Analog pressure sensor failureF3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms)F3E4Inlet thermistor is shorted; temperature above 760°F (<20 ohms)F3E5Moisture Sensor 2 Open/Shorted (only Quad Sense models).F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shortedF4E1No voltage detected at the heater relayF4E2Heater 2 failure or connector problem (electric models only); no voltage…F4E3Restricted air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F5 E1Lower dryer door circuit error.F5 E6Upper dryer door circuit error.F5-E0Excessive temperature in lower cavity during self-clean cycle.F6-E0Excessive temperature in lower cavity during bake mode.F6-E1Excessive temperature in microwave oven during cooking.F64Steamer inlet valve failureF66Steam temperature sensor (NTC) errorF6E1Communication between the CCU and UI has not been detected (UI to CCU).F6E2Communication between the CCU and UI has not been detected (CCU to UI).F6E3Communication errorF7 E6Lower dryer motor circuit error.F7 E7Upper dryer motor circuit error.F7 E8Lower dryer motor sense errorF7 E9Upper dryer motor sense errorF70Central Control Unit heartbeat failureF71User Interface heartbeat failureF74UI EEPROM failureF8-E0Self-clean latch unable to unlock.F8-E1Self-clean latch unable to unlock.F8-E2Excessive temperature in oven with door open and latch locked.F8-E3Excessive temperature in oven with door open and latch unlocked.F8-E4Excessive temperature in oven with door closed and latch unlocked.F99Not supportedFC E1Model/Serial number not programmed into control.FC E4USB stick failure (USB full, not detected, or not accessible).FC E5Software uploaded from USB stick does not match the model number of the machine.FP E1Coin 1 circuit errorFP E2Coin 2 circuit errorFP E3Card reader communication error.L2Low L2 voltage (less than 50V) detected at the CCU.PFPower failure occurred while the dryer was running.rLCleaning cycle unload indicationSudSuds lock
Service modes (26)
- Component ActivationFrom Service Diagnostics Diagnostics Home screen, select 'Component Activation'
- Customer-Focused Dryness Level Adjustment1. Turn cycle selector knob to an automatic cycle. 2. From the Automatic Cycle Main Screen, press…
- Diagnostic Mode["Enter Setup Mode first.","While in any of the set-up codes 1 through 6 (or while dAS displays if…
- Diagnostic Test Only["Execute with an empty drum.","Close the door.","Push POWER.","Select the DRAIN AND SPIN…
- Error History, Software Version, and Diagnostic Test["Washer must be empty and control must be in OFF state.","Close the door.","Select any one key…
- Fault code displayPress and hold the UPPER OFF button for 5 seconds.
- Fault Code Display and Clear["Activate Service Diagnostic Mode first.","Press and release the 3rd button to display the most…
- Fault/Error Code Display and Clear1. Activate Service Diagnostic Mode. 2. Press and release the 3rd button to display next error…
- Help Mode["Enter Setup Mode first.","While in special pricing option step 2.XX (or while dAS displays if…
- Install Diagnostics1
- Key Activation & Encoder Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
- Microwave power output test1
- Model/Serial Number Menu["Enter Help Mode.","While on the S0 screen, press the HEAVY DUTY key.","Use NORMAL key to advance…
- Quick Diagnostic TestFrom Diagnostics Home screen, select 'Error Diagnostic', then select 'Quick Diagnostic Test'
- Reset Modifiers and Options to Factory Default1
- Sabbath modeSabbath mode is indicated by 'SAB' symbol on the display.
- Service Diagnostic Mode["1
- Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
- Service Test Mode["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- Setup Mode["Stacked PD Models
- Software Version Display1
- Temperature offset calibrationAdjust temperature offset in increments of 3°C or 5°F
- Temperature unit conversion (F/C)Press and hold the BROIL button for 5 seconds to switch to Celsius (indicated by 'C' on display).
- UI Component TestFrom Diagnostics Home screen, select 'Component Activation', then select 'UI Component Test'
- USB Menu["Enter Help Mode.","While on the USB screen, press the HEAVY DUTY key.","Use NORMAL key to advance…
- User Interface/Control System Test1
Full entry steps, exit procedures, and test sequences are available in Max.