Skip to main contentGet Started
Error code reference
Amana Microwave Error Code F3-E3
Temperature sensor (microwave) shorted.
Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Diagnostic procedure
The full F3-E3 procedure
Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.
MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
1. Disconnect power or unplug oven. 2. Check microwave sensor connection. 3. Measure sensor resistance: 280kΩ at 70°F (21°C), 1kΩ at 392°F (200°C). If resistance is not valid replace sensor. 4. If sensor resistance and connections are good, check for welded-closed relays on the control. If relay shorted, replace control.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock F3-E3 procedure $9.95
Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass