Model reference
Amana RS-7A
Microwave
3 documents24 error codes13 service modes
Available documentation
Tech Sheet
- Tech Sheet - W11087920 - Rev A60 pg
- Tech Sheet - W10403269 - Rev A52 pg
Installation Guide
- Installation Instructions20 pg
MyPros+ Max
Diagnose your Amana RS-7A.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (24)
CodeMeaning
E1Temperature sensing circuit is open.E2Temperature sensing circuit is shorted.E3Blower rotational speed dropped below 500 RPMs during a cycle; all outputs…E4Tumbler rotational speed dropped to 0 during a cycle; all outputs turned off.E5Dry rack sensor signal lost during a Dry Rack cycle; all outputs turned off.E6Exhaust temperature exceeded 87.7°C (190°F); all outputs turned off.F1E1Indicates a CCU (Cycle Control Unit) problem.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; this…F2E2User Interface software errorF3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor has shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; this fault code will only appear when in the…F3E7Moisture sensor strip has shorted; this fault code will ONLY appear when in the…F4E1No voltage detected at the heater relay; this fault code appears ONLY when in…F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F6E1Communication error from UI to CCU; communication between the CCU and UI has…F6E2Communication error from CCU to UI; communication between the CCU and UI has…LLow L2 voltage (less than 50V) detected at the CCU; displayed on models 4000…L2Low L2 voltage (less than 50V) detected at the CCU.PFPower failure occurred while the dryer was running.Service modes (13)
- Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS LEVEL button…
- Diagnostic Test #1 - Controls Operation["Ensure dryer is in Standby Mode (plugged in, all indicators off).","Within 5 seconds, press
- Diagnostic Test #2 - Machine Operation["Ensure dryer is in Standby Mode (plugged in, all indicators off).","Within 3 seconds, press
- Fault Code Display and Clear["Activate Service Diagnostic Mode first.","Press and release the 3rd button to display saved fault…
- Install Diagnostics["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
- Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds: Press…
- Menu Mode (Gas/Electric Configuration)["Ensure dryer is in Standby mode (plugged in, all indicators off).","Within 3 seconds, press
- Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Select any three buttons…
- Software Version Display["First activate Service Diagnostic Mode.","Press and hold the 2nd button used to activate Service…
- Test #5a - User Interface Keypad Test["Unplug dryer or disconnect power.","Press and hold Start and Cycle End Tone buttons.","While…
- Test #5a - User Interface Keypad Test Mode["Unplug dryer or disconnect power.","Press and hold Start and Cycle End Tone buttons.","While…
- User Interface Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
- User Interface/Control System Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana microwave models
78,000+ service manuals · 160,000+ error codes · 55+ brands