Model reference
Amana SP19N-P60230-52W
Refrigerator
2 documents32 error codes5 service modes
Available documentation
Service Manual
- Built-in Coffee System76 pg
Tech Sheet
- Tech Sheet - W10531678 - Rev A (FR)_W1053167816 pg
MyPros+ Max
Diagnose your Amana SP19N-P60230-52W.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (32)
CodeMeaning
1-1Control module detected relay K1 stuck in closed position.1-2Control module software problem10-1Dispenser electrical problem2-1User interface3-1Temperature sensor/soil sensor3-2Temperature sensor/soil sensor3-3Soil sensor (OWI) calibration impossible4-3Wash motor non-operation5-1Door switch5-2Door switch stuck in closed position6-1Water inlet6-2Fill valve electrical problem6-3Excessive sudsing/air in pump.6-4Overfill float switch open6-6Water too cold7-1Heating7-2Heating element constantly energized8-1Slow drain8-2Drain motor electrical problem8-3Drain circuit constantly energized9-1Diverter valve problem9-2Diverter valve problem.ADD GROUND COFFEEThe ground coffee function has been selected without placing any ground coffee…CLOSE DOOR!The service door is open.DESCALE!The flowmeter has measured that the volume of water used exceeds the set limit…FILL BEANS CONTAINER!Coffee beans have run out, or clutch is obstructed by stones or foreign objects…FILL TANK!Water tank is empty, incorrectly positioned, or the reed sensor/float is…GENERAL ALARMInternal fault detected during startup or operation, caused by NTC failure…GROUND TOO FINE ADJUST MILLWater is running off too slowly due to fine grind setting, removed water tank…INSERT BREWING UNITThe brewing unit has not been replaced after cleaning.Service modes (5)
- cycle_step_throughPress and hold the Cycle Select button for 5 seconds
- diagnosticIn standby mode, press any 3 keys in sequence 1-2-3-1-2-3-1-2-3 with less than one second between…
- Display Test Mode["With the coffee system in standby (plugged in with the main switch on but the machine off), open…
- Load Test Mode["With the coffee system in standby (plugged in with the main switch on but the machine off), open…
- Reset Upper Position of Infuser["With the machine in standby (plugged in with the main switch on, but machine off), open the…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana refrigerator models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass