Model reference
GE PP950SM1SS
Cooktop
1 document20 error codes3 service modes
Available documentation
Service Manual
- GE Range PP950SM1SS Mini Manual2 pg
MyPros+ Max
Diagnose your GE PP950SM1SS.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (20)
CodeMeaning
102Communication failure between display board and main board.103Main board CPU failure.104Main board MUX failure.105Zero-cross failure.106EEPROM failure (hidden to user).107EEPROM failure (hidden to user).108Line monitor failure.160Pan detect communication failure.161Pan detect invalid data.170Open matrix key.171Shorted matrix key.172Ghost key.173Display board CPU failure.174Display board 8V supply failure.1X2Heater over temperature (X is sensor number 1-5).1X3Open temperature sensor (RTD) (X is sensor number 1-5).1X4Shorted temperature sensor (RTD) (X is sensor number 1-5).1X6Heater not heating (X is sensor number 1-5).1X7Inductive sensor frequency fault (X is sensor number 1-5).TEMP LTDTemperature limited heater; the particular heater will be disabled for 1/2 hour…Service modes (3)
- Calibration Mode (Inductive Sensors)1
- Software Revision DisplayPress TIMER ON/OFF, RF+, and RR+ keys at the same time
- Technician Mode1
Full entry steps, exit procedures, and test sequences are available in Max.
Related GE cooktop models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass