Model reference
Jenn-Air JGS1450ML0
Range
7 documents37 error codes21 service modes
Available documentation
Service Manual
- Dimension Guide10 pg
- SERVICE MANUAL - Whirlpool®, Maytag®, KitchenAid®, Kenmore®, JennAir®, IKEA®, and Amana® Ranges104 pg
Tech Sheet
- Tech Sheet - W11602648 - Rev A2 pg
- Tech Sheet36 pg
Service Flash
- Service Pointer - W11814535 - Rev A - Slide In Ranges - Flickering Oven Light3 pg
Tech Tip
- Cleaning Kit Offer1 pg
- Oven Cleaning Quick Reference Guide2 pg
MyPros+ Max
Diagnose your Jenn-Air JGS1450ML0.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (37)
CodeMeaning
C-81Over temperature (induction cooktop)C-82Over temperature (induction cooktop)C-83Temperature sensor stuckF-12Coil under currentF-21Supply power frequency errorF-25Stuck fan on Induction Power System (IPS) (Right or left side fan, depending on…F-36Temperature sensor is not workingF-37Temperature sensor is not workingF-40Induction Power System (IPS) failureF-42Power supply failureF-43Under voltageF-47Power supply from Induction Power Control (IPC) to User Interface is missing…F-56Wrong or invalid configurationF-58Wrong or invalid configuration (IPS)F-60UI does not workF1EEPROM communication error or internal control failure (Maxwell/MRC control).F1E0EEPROM Communication ErrorF1E1A/D error (LCC/LCX control).F1E2A/D error (LCC/LCX control).F2Keypad disconnected, stuck key, or cancel key error (Maxwell/MRC control).F2E0Keypad DisconnectedF2E1Stuck KeypadF3E0Main Oven Sensor Open or ShortedF3E1Oven sensor shorted (LCC/LCX control).F3E2Drawer Sensor Open or ShortedF3E3Clean range over temperature (LCC/LCX control).F5E0Door and door position switch do not agree during Clean mode (Maxwell/MRC…F5E1Door latch not operating during Clean mode (LCC/LCX control).F5E2Door and door position switches do not agree during Clean mode (LCC/LCX…F6E0Oven User Interface lost communication between UI and ACU (Indigo control).View all 37 error codes
Service modes (21)
- Auto Test - Maxwell/MRC Controls["Enter Diagnostics Mode (CANCEL>CANCEL>START)","Press the 'up' arrow, '+' key, or '3' key to…
- Auto Test (Automatic Test Mode)Enter Diagnostics Mode (CANCEL>CANCEL>START within 5 seconds), then press the number 3 or 6 keypads…
- Auto Test (Maxwell/MRC Controls)1
- Clear Error CodesEnter diagnostic mode by pressing CANCEL>CANCEL>START within 5 seconds
- Component Activation (Indigo Controls)From Diagnostics Menu, select Component Activation
- Diagnostics ModePress CANCEL > CANCEL > START within 5 seconds.
- Diagnostics Mode - Indigo Controls (Option 1)["Press HOME>FAVORITES>LIGHT (repeat this sequence three times in a row)","The warning will be…
- Diagnostics Mode - Indigo Controls (Option 2)["Press TOOLS>INFO>SERVICE AND SUPPORT","Press the Diagnostics button for 1 minute","Press…
- Diagnostics Mode - LCC/LCX Controls["Press CANCEL","Press CANCEL","Press START (all within a 5-second period)","Initial display shows…
- Diagnostics Mode - Maxwell/MRC Controls["Press CANCEL","Press CANCEL","Press START (all within quick succession)","Display shows 'TEST ON'…
- Diagnostics Mode (Indigo Controls) - Option 1Press HOME > FAVORITES > LIGHT, repeat three times in a row
- Diagnostics Mode (Indigo Controls) - Option 2Press TOOLS > INFO > SERVICE AND SUPPORT
- Diagnostics Mode (LCC/LCX Controls)Press CANCEL > CANCEL > START within a 5-second period. Scroll through settings with up arrow…
- Diagnostics Mode (Maxwell/MRC Controls)Press CANCEL > CANCEL > START within 5 seconds
- Diagnostics Test Mode Relay Checks (LCC/LCX Controls)While in Diagnostics Mode
- Faults Viewing/ClearingEnter Diagnostics Mode (CANCEL>CANCEL>START within 5 seconds), then press the number 3 or 6 keypads…
- Service Modes - Maxwell/MRC Controls (TEST ON, USAGE, ENG MODE, TEST MODE, VERSION, DISPLAY, FAULTS, EXTERNAL FAULTS, RELAY USAGE, AUTO TEST)["Press CANCEL>CANCEL>START to enter Service Mode","Use up arrow/+ key/3 key to scroll through…
- Service Modes Menu (Maxwell/MRC Controls)Press CANCEL>CANCEL>START. Scroll through modes using up arrow/'+'/3 key
- Temperature CalibrationPress the Settings or Options keypad until 'Temp Calib' is displayed
- Test Mode (Manual Relay Activation)Enter Diagnostics Mode (CANCEL>CANCEL>START within 5 seconds), then press the number 3 or 6 keypads…
- TEST ON - Relay Checks (Maxwell/MRC Controls)From Diagnostics Mode (CANCEL>CANCEL>START), at TEST ON display
Full entry steps, exit procedures, and test sequences are available in Max.