Model reference
KitchenAid KHGV01RSS0
Dryer
4 documents7 error codes4 service modes
Available documentation
Tech Sheet
- Tech Sheet 395766816 pg
Tech Tip
- Instruction Sheet2 pg
Installation Guide
- Instruction Sheet2 pg
- Instruction Sheet2 pg
MyPros+ Max
Diagnose your KitchenAid KHGV01RSS0.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (7)
CodeMeaning
E1Temperature sensing circuit is open.E2Temperature sensing circuit is shorted.E3Blower rotational speed dropped below 500 RPM during a cycle, all outputs…E4Tumbler rotational speed dropped to 0 during a cycle, all outputs turned off.E5Dry rack sensor signal lost during a Dry Rack cycle, all outputs turned off.E6Exhaust temperature exceeded 87.7°C (190°F), all outputs turned off.PFPower failure occurred while the dryer was running.Service modes (4)
- Diagnostic Test #1 - Controls Operation["Ensure dryer is in Standby Mode (plugged in, all indicators off).","Within 5 seconds, press
- Diagnostic Test #2 - Machine Operation["Ensure dryer is in Standby Mode (plugged in, all indicators off).","Within 3 seconds, press
- Menu Mode (Gas/Electric Configuration)["Ensure dryer is in Standby Mode (plugged in, all indicators off).","Within 3 seconds, press
- Test #5a - User Interface Keypad Test["Unplug dryer or disconnect power.","Press and hold Start and Cycle End Tone buttons.","While…
Full entry steps, exit procedures, and test sequences are available in Max.