Model reference
Magic Chef 31FS-8KLX-OC
Range
1 document43 error codes9 service modes
Available documentation
Tech Sheet
- TECH SHEET - W10159200 - Rev A6 pg
MyPros+ Max
Diagnose your Magic Chef 31FS-8KLX-OC.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (43)
CodeMeaning
1-1Control detected K1 pilot relay stuck closed.1-2Control software issue10-1Dispenser electrical problem10-3Drying fan error2-2No response from User Interface (UI)3-1Open connector or component in Temperature Sensing circuit; open or faulty…3-2Shorted temperature sensing circuit3-3Failed OWI calibration4-3Wash motor not running5-1Door stuck open5-2Door stuck closed6-1Low/no water (mechanical problem)6-2Fill valve electrical problem6-3Suds/air in pump6-4Float switch open7-1No heat7-2Heater stuck on8-2Drain motor electrical problem9-1Diverter can't find position9-2Diverter stuck on9-3Diverter disc missingDoorDoor Interlock Primary Switch issue.E0-F1EEPROM communications failure, typically caused by power line noise or…E0-F2EEPROM checksum failure, typically caused by power line noise or lightning.E0-F3Key contact closed for more than 60 secondsE0-F5Clean temperature out of range (too high)E1Thermistor is open (open circuit detected).E1-F1EEPROM communications failure, typically caused by power line noise or…E1-F2EEPROM checksum failure, typically caused by power line noise or lightning.E1-F3Break in oven sensor circuit (open sensor, loosened or disconnected sensor…View all 43 error codes
E1-F5Door switch open during clean cycleE2Thermistor has shorted (short circuit detected).E2-F3Short in oven sensor circuit (short in sensor, sensor shorted to casing…E3User interface keyswitch or software mismatch between the control…E3-F3BAKE/BROIL temperature out of range (too high)Err1Failed H.VErr2Failed H.VErr3Failed H.VErr4Failed H.VErr5Shorted Touch Panel.Err6Failed H.VHOTThermal cutout has tripped due to overheating conditions (open magnetron TCO…PFPower failure occurred while the dryer was running.
Service modes (9)
- Diagnostic Test Mode["Unit must be in Standby mode (plugged in, display off).","Alternately press the Less Time (∨) and…
- Forced Defrost Mode["1
- Manual Diagnostics Mode 1 (Full - within 120 seconds of power up)Within 120 seconds of power-up, press Cancel/OFF, Cancel/OFF, then Start
- Manual Diagnostics Mode 2 (Limited - after 120 seconds of power up)After 120 seconds of power-up, press Cancel/OFF, Cancel/OFF, then Start
- Programming Mode["1
- Service Diagnostics CycleWhile in Standby, press any 3 keys in the sequence 1-2-3-1-2-3-1-2-3 with no more than 1 second…
- Service Diagnostics with Error CodesPress any 3 keys in the sequence 1-2-3-1-2-3-1-2-3 with no more than 1 second between key presses.
- Service Test Mode["Unit must be in OFF condition or INITIAL power up mode.","Close oven door.","Press the Hidden Pad…
- Temperature Adjustment (Calibration)Press and hold BAKE pad for 5 seconds
Full entry steps, exit procedures, and test sequences are available in Max.
Related Magic Chef range models
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass