Model reference
Magic Chef BT18PS-4T
Range
12 documents76 error codes51 service modes
Available documentation
Service Manual
- Freestanding Double Oven Gas Range Service Manual69 pg
- Service Manual - Freestanding Double Oven Gas Range69 pg
- Maytag Gemini Freestanding Double Oven Gas Range Service Manual69 pg
- Gas Freestanding Range Base Manual42 pg
- Electric Slide-In Range Base Manual67 pg
- Service Manual - Electric Slide-In Range67 pg
- Electric Slide-In Range Service Manual67 pg
- Maytag Freestanding Range Repair Service Manual42 pg
- Service Manual - Gas Freestanding Range42 pg
Tech Sheet
- Tech Sheet - W10434985 - Rev A8 pg
- Tech Sheet - W10384452 - Rev A8 pg
Tech Tip
- Instruction Sheet - 85231538 pg
MyPros+ Max
Diagnose your Magic Chef BT18PS-4T.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (76)
CodeMeaning
1c1cShorted key detected on the membrane keyboard.1c2cMembrane keyboard disconnected from the control board.1c31Cancel key circuit problem (cancel key improper value).1c32Cancel key circuit problem (cancel key improper value, second instance).1c4cBoard-to-board communication failure.1c6cEEPROM hardware fault.1c7cControl not calibrated.1c81EEPROM CRC error in Cook Profile data.1c8cEEPROM CRC error in User Options data.1d11Unlocked runaway oven temperature exceeding 600°F.1d12Runaway temperature (650°F) detected with door unlocked (second instance)…1d21Locked runaway oven temperature exceeding 950°F.1d22Runaway temperature (950°F) detected with door locked (second instance); sensor…3d11Oven temperature sensor circuit is open.3d12Oven temperature sensor open (second instance)3d21Oven temperature sensor circuit is shorted.3d22Oven temperature sensor shorted (second instance)3d41Meat probe circuit is shorted.3d51Meat probe not calibrated.4d11Door switch not closed when door is locked.4d12Door switch position failure (second instance)4d21No cooling fan rotation detected.4d31Cooling fan is on when it should be de-energized.4d41Cooling fan overspeed condition detected.4d51Door switch circuit fault.4d52Door switch circuit failure (second instance)9d11Door latch will not lock.9d12Latch will not lock (second instance)9d21Door latch will not unlock.9d22Latch will not unlock (second instance)View all 76 error codes
9d31Door latch reports both locked and unlocked simultaneously.9d32Latch state unknownEEControl cannot read E-PROM; unit will shut down.F0-0No faultF1Internal board failure (F1E0, F1E1, F1E2 on LCC 180/190).F1-1Upper oven temperature exceeds 650°F with door unlocked.F1-2Lower oven temperature exceeds 650°F with door unlocked.F1-3Upper oven temperature exceeds 950°F with door locked.F1-4Lower oven temperature exceeds 950°F with door locked.F1-5Upper hardware failure within control.F1-6Lower hardware failure within control.F1-7Membrane switch is not responding.F1-8Shorted key in membrane switch.F1-9Internal communication errors within control.F1-AUpper latch switches failure.F1-BLower latch switches failure.F1-CUpper door switch failure.F1-DLower door switch failure.F1-ESensor input not calibrated.F1-HEEPROM error.F1-LTemperature in ovens are the same for a long period.F1-NInternal voltage on control not working.F1E0Internal board failure.F1E1Internal board failure.F1E2Internal board failure.F2Shorted key / A/D Error(s) (F2E0 on LCC 180/190).F2E0Shorted key.F3Oven sensor opened, oven sensor shorted, BAKE/BROIL range over temperature, or…F3-1Upper sensor is shorted (<100 ohms) or open (>5K ohms).F3-2Lower sensor is shorted (<100 ohms) or open (>5K ohms).F3E0Oven sensor opened.F3E1Oven sensor shorted.F3E2Bake/Broil range over temperature.F3E3Clean range over temperature.F5Door and switches do not agree during Clean mode (F5E0, F5E2 on LCC 180/190).F5E0Door and switches do not agree (clean mode).F5E1Door latch not operating (clean mode).F5E2Door and switches do not agree (clean mode).F9Miswired house or miswired range (F9E0 on LCC 180/190).F9-1Upper lock switch is not correct.F9-2Upper unlock switch is not correct.F9-3Control does not see upper door lock.F9-4Lower lock switch is not correct.F9-5Lower unlock switch is not correct.F9-6Control does not see lower door lock.F9E0Miswired house or miswired range.
Service modes (51)
- 24 Hour Clock Toggle (H1/M2 Control)Press and hold Cancel and Favorite pads for 3 seconds.
- 24 Hour Clock Toggle (M1 Control)Press and hold Cancel and Delay pads for 3 seconds.
- Child Lock OutPress and hold Cancel and Cook & Hold pads for 3 seconds
- Child Lock Out (H1/M1/M2 Control)["Press and hold Cancel and Cook & Hold pads for 3 seconds.","'OFF' will display where temperature…
- Clock Display TogglePress and hold Cancel and Clock pads for 3 seconds.
- Control LockoutPress the Back and Setup pads simultaneously for 5 seconds to lock.
- Control Reset1
- control_lockoutPress the Back and Setup pads simultaneously for 5 seconds to lock.
- control_reset1
- Demo Mode1
- Diagnostic Code Display ModePress and hold the AUTOSET pad for 3 seconds at power-up (must be entered only when applying power…
- Diagnostic Code Display Mode (H1 Control)Press and hold the AUTOSET pad for 3 seconds at power-up
- Diagnostic Code Display Mode (H2 Control - MGR6875AD*)Press and hold the AUTOSET pad for 3 seconds at power-up
- Diagnostic Code Display Mode (H3 Control - MGR6775AD*)Press and hold Upper Cancel and Timer for 3 seconds within 5 minutes of power up.
- Diagnostic Code Display Mode (M1 Control)Press and hold Up Arrow pad while powering up the unit
- Diagnostic Code Display Mode (M1/M2 Control)Press and hold the Up Arrow pad and power up the unit
- Diagnostic Code Display Mode (M2 Control)Press and hold Up Arrow pad while powering up the unit
- Diagnostics ModePress CANCEL > CANCEL > START within a 5-second period.
- Diagnostics Test Mode (Relay Checks)While in Diagnostics Mode, press the following keypads to test individual control relays
- Display Test1
- display_test1
- Engineering Test ModePress BAKE pad, enter 100°F using number pads, immediately push and hold BAKE pad for approximately…
- Engineering Test Mode (H3 Control - MGR6775AD*)Press BAKE pad, enter 100°F using number pads, immediately push and hold BAKE pad for approximately…
- Factory Default ResetPress and hold Cancel and Keep Warm pads for 3 seconds.
- Faults Access1
- faults_access1
- Oven Temperature Adjustment (H1 Control)["Press BAKE pad.","Enter 550 on the digit-pad.","Immediately press and hold BAKE pad for 3…
- Oven Temperature Adjustment (H1/M1/M2 Control)1
- Oven Temperature Adjustment (H1/M1/M2 Controls)1
- Quick Test ModePress and hold UPPER CANCEL and BROIL pads for 3 seconds
- Quick Test Mode (EOC III)1
- Quick Test Mode (ERC)1
- Quick Test Mode (H1 Control)1
- Quick Test Mode (H2 Control - MGR6875AD*)Press and hold Upper Cancel and Autoset pads for 3 seconds.
- Quick Test Mode (H2 Control)1
- Quick Test Mode (H3 Control - MGR6775AD*)Press and hold Upper Cancel and Timer pads for 3 seconds within 5 minutes of power up.
- Quick Test Mode (M1/M2 Control)1
- quick_test1
- Sabbath ModeHold CLOCK pad for 3 seconds to activate Sabbath mode.
- Sabbath Mode (H1/M1/M2 Control)["Hold CLOCK pad for 3 seconds to activate Sabbath mode."]
- Service Mode1
- service_mode1
- Setup Options (Quick Test sub-mode)During Quick Test mode, press the 0 pad
- Setup Options (within Quick Test Mode)While in Quick Test Mode, press the 0 pad
- Software Versions Access1
- software_versions_access1
- Temperature Adjustment1
- Temperature Adjustment ModeStep 1
- Temperature Display Toggle (F/C)Press and hold Cancel and Bake pads for 3 seconds.
- Test Mode1
- Test Mode (H3 Control - MGR6775AD*)1
Full entry steps, exit procedures, and test sequences are available in Max.
Related Magic Chef range models
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax