Model reference
Magic Chef U22FK-2LXY-6D
Range
6 documents31 error codes9 service modes
Available documentation
Tech Sheet
- Model Spec and Wiring Sheet - W10578500 - Rev A6 pg
- Wiring Diagram - W10470607 - Rev A6 pg
Installation Guide
- Installation Instructions4 pg
- Installation Instructions16 pg
- ventilation-specification-W10200920D.pdf8 pg
- Installation Instructions16 pg
MyPros+ Max
Diagnose your Magic Chef U22FK-2LXY-6D.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (31)
CodeMeaning
C2Compressor error.F1FC or RC fan error.F1E1Indicates a CCU (Cycle Control Unit) problem.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; this…F2E2UI cannot read EEPROM software from the User Interface.F3FC or RC fan error.F3E1Exhaust thermistor is open; temperature drops below 18°F (> 50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (< 500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (> 245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (< 328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if the P14 connector is…F3E6Moisture sensor strip is open; this fault code will only appear when in the…F3E7Moisture sensor strip has shorted; this fault code will ONLY appear when in the…F4E1No voltage detected at the heater relay; appears ONLY when in the Diagnostic…F4E3Restricted air flow that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F6E1Communication between the CCU and UI has not been detected (UI to CCU…F6E2Communication between the CCU and UI has not been detected (CCU to UI…H1Defrost heater error.H2Defrost heater error.H3Defrost heater error.H4Defrost heater error.L2Low L2 voltage (less than 50V) detected at the CCU.OPThermistor measurement is lower than the COLD limit, indicating an open circuit.PFPower failure occurred while the dryer was running.S1FC compartment sensor shorted or open.S2RC compartment sensor shorted or open.S3FC evaporator sensor shorted or open.S4RC evaporator sensor shorted or open.S5Ambient sensor shorted or open.View all 31 error codes
Service modes (9)
- Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS LEVEL button…
- Install Diagnostics["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
- Loads Test Mode["Ensure the dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds…
- Service Diagnostic Mode["Ensure the dryer is in standby mode (plugged in with all indicators off).","Select any three (3)…
- Service Diagnostics Mode["Ensure the refrigerator is not in a lockout mode (Showroom Mode, Cooling Off, or Sabbath…
- Showroom Mode Exit["Press and hold FRIDGE and FREEZER keys for 3 seconds to exit Showroom Mode."]
- Software Version Display["First activate Service Diagnostic Mode.","Press and hold the 2nd button used to activate Service…
- User Interface Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
- User Interface/Control System Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Magic Chef range models
78,000+ service manuals · 160,000+ error codes · 55+ brands