Model reference
Maytag MEDX500XW1
Dryer
5 documents18 error codes7 service modes
Available documentation
Tech Sheet
- Tech Sheet – do not Discard8 pg
- Tech Sheet - W10417013 - Rev C64 pg
Wiring Diagram
- Whirlpool Dryer WED5600XW0 Wiring Sheet1 pg
Installation Guide
- Installation Instructions20 pg
- Instrucciones de instalacion22 pg
MyPros+ Max
Diagnose your Maytag MEDX500XW1.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (18)
CodeMeaning
E1Thermistor is open.E2Thermistor has shorted.E3User interface keyswitch or software mismatch (only appears in diagnostic test…f1 e1Primary control failure.F1E1Primary control failure indicating the machine control electronics has failed.f2 e1Stuck button or user interface mismatch (only appears in service diagnostic…F2E1Stuck button or user interface mismatch; this fault code will ONLY appear when…f3 e1Exhaust thermistor is open.f3 e2Exhaust thermistor has shorted.f3 e6Moisture sensor strip is open (only appears in service diagnostic mode).f3 e7Moisture sensor strip has shorted (only appears in service diagnostic mode).F3E1Exhaust thermistor is open.F3E2Exhaust thermistor has shorted.F3E6Moisture sensor strip is open; this fault code will ONLY appear when in the…F3E7Moisture sensor strip has shorted; this fault code will ONLY appear when in the…f4 e4Low line voltage detected.F4E4Low line voltage detected.pfPower failure occurred while the dryer was running.Service modes (7)
- Customer-Focused Drying Mode Adjustment1
- Diagnostic Test Mode["Ensure dryer is in standby mode (plugged in, all indicators off).","Press the following button…
- Diagnostic: Console switches and indicators["Enter Diagnostic Test Mode.","Press each button or turn the cycle selector to each cycle.","Each…
- Diagnostic: Door Switch["Enter Diagnostic Test Mode.","Open the door
- Diagnostic: Moisture Sensor["Enter Diagnostic Test Mode.","Locate two metal strips on the face of the lint screen…
- Service Diagnostic Mode1
- User Interface/Control System TestFrom within Service Diagnostic Mode, press and release the 1st button used to activate Service…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Maytag dryer models
78,000+ service manuals · 160,000+ error codes · 55+ brands