Error code reference
Maytag Dryer Error Code F2 E1
Dryer keypad is sensed pressed for 10 seconds (stuck key error); fault will auto-clear after 30 seconds if…
Dryer keypad is sensed pressed for 10 seconds (stuck key error); fault will auto-clear after 30 seconds if keypad is determined to not be pressed.
First step from the service manual
1
Check keypad/membrane switch.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
MyPros+ Max
Get the full diagnostic procedure for F2 E1.
- ✓Step-by-step tests with expected resistance, voltage, and continuity values
- ✓Wiring diagram references and connector pinouts from the OEM service manual
- ✓Verified part numbers when replacement is required
Get the full procedure→
$29/month · Cancel anytime · Or $9.95 3-day pass
M+
M+ Max·Maytag Dryer
F2 E1 on my Maytag MED7230HW
M+
Dryer keypad is sensed pressed for 10 seconds
From Tech Sheet W12075307, p.39:
1.Check keypad/membrane switch.
2.Measure control board supply voltage at the test points. Expected: 12 VDC and 5 VDC; a drop below 4.75 VDC on the logic rail points to a failed onboard regulator.
3.Inspect all connectors on the main control for corrosion, thermal stress, or backed-out pins. Reseat each connector with the power disconnected.
Part WPW10804018
Electronic control board
Related Maytag dryer codes
All Maytag dryer codes →- 0No code present (no fault detected).
- 00No diagnostic codes available
- 01Thermistor short sensed
- 02Thermistor open sensed
- 03Door circuit failure
- 04Possible motor transistor error
- 06Non-volatile memory problem
- 08Stuck key
View all 251 Maytag dryer codes
- 1Lower Dryer Thermistor Short Sensed
- 10No wet clothes
- 11Upper Dryer Thermistor Short Sensed
- 12Upper Dryer Thermistor Open Sensed
- 13Upper Dryer Door Circuit Failure
- 14Heater on and drum temperature not increasing.
- 15Thermistor possible open.
- 16Thermistor possible short.
- 17Motor thermal protector opened more than 5 times during…
- 18Motor thermal protector opened more than 5 times during…
- 2Lower Dryer Thermistor Open Sensed
- 20Dryer over temperature without shutdown.
- 21Selected dryer temperature not reached.
- 22Dryness sensor bar possibly open.
- 23Dryness sensor bar possibly shorted.
- 24Incorrect rotary switch position seen.
- 25Rotary Switch 1 left of encoder failed at startup.
- 26Rotary Switch 2 left of encoder failed at startup.
- 28Rotary Switch 3 left of encoder failed at startup.
- 3Door switch related error code; indicates a door switch…
- 31Model ID Unknown, default used at startup.
- 4Possible motor transistor error
- 5Not used.
- 6Non-volatile memory error
- 8Stuck key
- 88Help code
- ACCUDryer motor control circuit error
- AFRestricted/low air flow detected that may affect dryer…
- AXIAL PROBE FAULTProblem with the axial temperature sensor circuit.
- bC.1Blocked coin 1 or coin drop control circuit failure (coin…
- bC.2Blocked coin 2 or coin drop control circuit failure (coin…
- BURNER CONTROL FAULTGas return valve signal did not turn on before DSI purge…
- BURNER HIGH LIMIT FAULTThe temperature disk in the burner has opened (burner…
- BURNER IGNITION CONTROL FAULTNo signal to gas valve from Direct Spark Ignition (DSI)…
- BURNER PURGE FAULTControl detected presence of gas return signal before…
- C1Blocked coin 1 or coin drop control circuit failure (coin…
- C2Blocked coin 2 or coin drop control circuit failure (coin…
- CCU error (motor feedback - stacked)CCU error
- CCU error (motor feedback with door open)CCU error
- CHECK CONTROL BOARD FUSE #2Main fuse (fuse 2) on the Phase 7 control board has opened…
- CLEAN LINTLint cleaning frequency timer has expired; lint drawer must…
- Co.EPN Models Only
- Coin 1Coin 1 failure. For PN models
- Coin 2 FailureCoin 2 failure detected.
- dUI Microprocessor is not able to read or verify EEPROM
- d-01Blocked coin 1 or coin drop UI control circuit failure…
- d-02Blocked coin 2 or coin drop UI control circuit failure…
- d-03Not receiving communications from installed debit card…
- d-10Voltage detected below 90 VAC for 8 seconds.
- d-26UI is not receiving communications from CCU (cycles and…
- d-30UI Microprocessor is not able to read or verify EEPROM…
- d-31UI EEPROM memory is a CRC failure (cycles and price display…
- d0Lower dryer door sense error on control board or due to…
- d1Upper dryer door sense error on control board or due to…
- d12Motor sense error on control board or due to power line…
- d13Blocked coin 2 or coin drop control circuit failure (coin…
- d14Upper dryer motor sense circuit error on control board or…
- D15Lower Burner Return Voltage Fault (stack dryers only)
- D16Gen 2 Card Reader Communication Fault
- d17Lower dryer door sense error on control board or due to…
- D18Axial Probe Fault
- D19Exhaust High Temp Fault
- d2Lower dryer motor control circuit error (lower dryer cycles…
- D20Sail Switch Open Fault
- D21Sail Switch Closed Fault
- D22Latched Heat Relay Fault
- D23Burner Return Voltage Fault
- d3UI Microprocessor is not able to read or verify EEPROM…
- d4Dryer motor control circuit error (single dryer)
- d5Lower dryer motor sense circuit error on control board or…
- d6Blocked coin 2 or coin drop control circuit failure (coin…
- d7Upper dryer motor sense circuit error on control board or…
- d8PN Models Only
- d9Upper dryer motor control circuit error (upper dryer cycles…
- dCDryer motor control circuit error (cycles and customer…
- DISCONNECTED WATER VALVES.A.F.E
- dLVoltage detected below 90 VAC for 8 seconds.
- dMDryer motor control circuit error; cycles and price display…
- dODoor Open Error
- donEDrying and cooling cycles complete or dryer is in…
- dOOrDoor or lint drawer switch circuit is open, indicating a…
- dr.LLower dryer motor control circuit error (lower dryer cycles…
- dr.UUpper dryer motor control circuit error (upper dryer cycles…
- dSDryer door sense error on control board or due to power…
- dS.LLower dryer door sense error on control board or due to…
- dS.UUpper dryer door sense error on control board or due to…
- dSFLTemperature sensor connection fault displayed when power is…
- E1Radiant Sensor Fault Count
- E2Burner Igniter Fault Count
- E3User interface or software mismatch between console…
- E4Lower Radiant Sensor Fault Count (stack dryers only)
- E5Lower Burner Igniter Fault Count (stack dryers only)
- E6Lower Exhaust High Limit (stack dryers only)
- E7Bad Coin Count (Coin 1)
- E8Bad Coin Count (Coin 2)
- E9Forward Rotation Sensor Fault Count
- EAReverse Rotation Sensor Fault Count
- EdNot receiving communications from installed debit card…
- EE PROM FAULT ###Error in memory location; the ### indicates the specific…
- EXHAUST HIGH TEMP FAULTOverheating detected; temperature sensor input showed…
- EXHAUST HIGH-LIMIT FAULTBasket (tumbler) safety over-temperature switch has opened.
- EXHAUST PROBE FAULTProblem with the exhaust temperature sensor circuit.
- FDryer motor control circuit error
- F-01Dryer door sense error on CCU control board or due to power…
- F-02Dryer motor control circuit error
- F-22Exhaust thermistor open
- F-23Exhaust thermistor shorted
- F-24Inlet thermistor is open (only appears in diagnostic test…
- F-25Inlet thermistor has shorted (only appears in diagnostic…
- F-9Low voltage (below about 95 volts); dryer will operate and…
- F:01Primary control failure.
- F:02Stuck button or user interface mismatch (appears ONLY in…
- F:20No voltage detected at the heater relay (appears ONLY in…
- F:22Exhaust thermistor is open.
- F:23Exhaust thermistor has shorted.
- F:24Inlet thermistor is open (appears ONLY in diagnostic test…
- F:25Inlet thermistor is shorted (appears ONLY in diagnostic…
- F:26Motor drive system failure.
- F:28Moisture sensor strip is open (appears ONLY in Diagnostic…
- F:29Moisture sensor strip has shorted (appears ONLY in…
- F:30Restricted air flow condition exists (appears ONLY in…
- F:31Low voltage condition (less than 30V) detected (appears…
- F:50No voltage detected at the water valve relay (appears ONLY…
- F:70No communication between the machine control and the…
- F:71No communication between the machine control and the…
- F:72Console electronics failure (F:72 through F:78).
- F:73Console electronics failure (F:72 through F:78).
- F:74Console electronics failure (F:72 through F:78).
- F:75Console electronics failure (F:72 through F:78).
- F:76Console electronics failure (F:72 through F:78).
- F:77Console electronics failure (F:72 through F:78).
- F:78Console electronics failure (F:72 through F:78).
- F0 E7Low Voltage Error
- F1Dryer motor control circuit error (cycles and price display…
- F1 E4HMI (Human Machine Interface) fault detected.
- F1 E6Voltage input fault detected by the control.
- F1 E7ACU Voltage Input Fault
- F10Upper thermistor circuit failure (stack dryer)
- F13Upper thermistor temperature too high (stack dryer)
- F14Lower thermistor temperature too high (stack dryer)
- F15Lower dryer motor control circuit failure (stack dryer)
- F16Lower thermistor circuit failure (stack dryer)
- F1E1Motor circuit is open or shorted, OR heat system is open or…
- F1E3Incorrect controller installed (electric models only); ACU…
- F1E5ACU parameter file missing; parameter memory invalid.
- F2Exhaust thermistor open
- F2 E2Upper Dryer Keypad Stuck Error
- F27Blocked coin 2 or coin drop UI control circuit failure…
- F2E3User Interface and ACU model ID parameter mismatch caused…
- F2E4UI software error
- F2E5UI software error
- F3Exhaust thermistor shorted
- F3E1Exhaust thermistor is open or shorted; open if temperature…
- F3E2Moisture sensor strip is open or shorted; this fault code…
- F3E3Inlet thermistor open or shorted; open if temperature below…
- F3E4Inlet thermistor is shorted; temperature above 760°F (<20…
- F3E5Inlet and exhaust thermistors are both open; will occur if…
- F3E6Moisture sensor strip is open; this fault code will only…
- F3E7Rear moisture sensor strip is open or shorted (Maytag…
- F4CCU is not receiving communications from UI (cycles and…
- F4E1No voltage detected at the heater relay; this fault code…
- F4E2Heater 2 failure or connector problem (electric models…
- F4E3Restricted/low air flow detected that may affect dryer…
- F4E4Low L2 voltage (less than 50V) detected at the ACU…
- F4E5High limit exceeded; temperature threshold of the dryer has…
- F5Dryer motor control circuit error (cycles and price display…
- F5 E1Lower Dryer Door Circuit Error
- F5 E6Upper Dryer Door Circuit Error
- F6UI Microprocessor is not able to read or verify EEPROM…
- F6 E1Communication Failure Between ACU and UIC
- F6E2Communication error
- F6E3Communication error
- F7Dryer motor sense failure
- F7 E6Lower Dryer Motor Circuit Error
- F7 E7Upper Dryer Motor Circuit Error
- F7 E8Lower Dryer Motor Sense Error
- F7 E9Upper Dryer Motor Sense Error
- F8Blocked coin 2 or control circuit failure
- FC E1Model/Serial not Programmed
- FC E2Model and serial numbers stored in ACU and UIC do not match.
- FC E3Wi-Fi connection fault.
- FC E4USB Fault
- FC E5Software Update Failure
- FC E6Model Setup Export Failure
- FC E7Model Setup Import Failure
- FC E8Wi-Fi module not responding or not connected.
- FEPower source frequency error
- FILLNo cycle in progress; the dryer is in normal stop mode…
- FLAME FAULTFlame was detected during trial for ignition but failed…
- FP E1Coin 1 Circuit Error
- FP E2Coin 2 Circuit Error
- FP E3Card Reader Communication Error
- Gen 2 Debit CardGeneration 2 Debit Card diagnostic code.
- h1A temperature increase has not been detected on the lower…
- h11A shaker assembly neutral fault has been detected; shaker…
- hEHeater error
- HotOverheating condition detected; the DMC computer has…
- HPThe thermistor reading is out of range and the dryer cycle…
- i5Heater temperature control problem.
- IGNITION FAULTGas valve return signal was lost during DSI proof time and…
- Invalid dryer door circuit stateInvalid dryer door circuit state
- LLow L2 voltage (less than 50V) detected at the CCU…
- L2Low L2 voltage (less than 50V) detected at the CCU…
- LdCLower dryer motor control circuit error (lower dryer cycles…
- LdSLower dryer door sense error on control board or due to…
- LINT ACCESS OPENThe lint drawer is open and needs to be closed.
- LMSLower dryer motor sense circuit error on control board or…
- LoVoltage detected below 90 VAC for 8 seconds.
- Lo.UVoltage detected below 90VAC for 8 seconds.
- Low voltageLow voltage condition detected (below approximately 90 VAC).
- LOW VOLTAGE FAULTPower has dropped below the operating values and the system…
- Lower dryer door sense errorLower dryer door sense error on control board or due to…
- MAIN DOOR OPENEDA main door is open when it should be closed.
- MODEL ERRORThe wrong model was selected for the dryer.
- MODEL ERROR, ENTER CORRECT MODELController detected input signals (sail switch, gas valve)…
- MSMotor sense error on control board or due to power line…
- no.LLower dryer motor sense circuit error on control board or…
- no.UUpper dryer motor sense circuit error on control board or…
- oPThermistor is open (infinite resistance) or temperature…
- OPEN EXHAUST TEMPERATURE PROBEThe exhaust temperature probe is open or shorted.
- OPEN S.A.F.E. SYSTEM PROBE FAULTThe temperature probe for the S.A.F.E
- OPEN THERMISTOR PROBES.A.F.E
- PFA power failure occurred during an active or paused cycle.
- PUSHAmount to start has been inserted; make temperature…
- ROTATION FAULTThe basket (tumbler) is not rotating.
- ROTATION SENSOR FAULTTime between rotational sensor pulses exceeded 10 seconds…
- S.A.F.E. SYSTEM ACTIVATEDControl has detected a fire in the basket (tumbler) and is…
- S.A.F.E. SYSTEM DISABLED READYA fault has been detected in the S.A.F.E
- S.A.F.E. SYSTEM WAS ACTIVATEDControl detected a fire and has completed extinguishing the…
- SAIL SWITCH CLOSED FAULTSail switch is in the closed position at startup or…
- SAIL SWITCH OPEN FAULTSail switch did not close within 8 seconds of…
- SEFLRotational sensor circuit failure indicating a fault in the…
- SHThermistor is shorted (zero ohms resistance) or temperature…
- SHORTED THERMISTOR PROBES.A.F.E
- SHORTED WATER VALVES.A.F.E
- TRACExhaust thermistor open
- tSDryer thermistor short sensed
- UdCUpper dryer motor control circuit error (upper dryer cycles…
- UdSUpper dryer door sense error on control board or due to…
- UMSUpper dryer motor sense circuit error on control board or…
- Upper dryer motor control circuit errorUpper dryer motor control circuit error
- Upper dryer motor sense circuit errorUpper dryer motor sense circuit error on control board or…
- WATER NOT CONNECTEDNo water pressure at the S.A.F.E
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started →$29/month · Cancel anytime · Or $9.95 3-day pass