Model reference
Amana C7-AG
Freezer
96 error codes30 service modes
MyPros+ Max
Diagnose your Amana C7-AG.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (96)
CodeMeaning
1c1cShorted key detected on the control circuit board keyboard.1c2cKeyboard tail disconnected or keyboard loop has improper value.1c31Cancel key circuit problem (cancel key improper value) on upper/single oven…1c32Cancel key circuit problem (cancel key improper value) on lower oven cavity.1c4cPower micro communication failure (CRC invalid).1c6cEEPROM error1c7cControl not calibrated1c81Cook profile corrupted in EEPROM for upper/single oven cavity (CRC invalid).1c82Cook profile corrupted in EEPROM for lower oven cavity (CRC invalid).1d11Runaway temperature (650°F) detected with door unlocked on upper/single oven…1d12Runaway temperature (650°F) detected with door unlocked on lower oven cavity.1d21Runaway temperature (950°F) detected with door locked on upper/single oven…1d22Runaway temperature (950°F) detected with door locked on lower oven cavity.3d11Temperature sensor failure (open) on upper/single oven cavity3d12Temperature sensor failure (open) on lower oven cavity3d21Temperature sensor failure (short) on upper/single oven cavity3d22Temperature sensor failure (short) on lower oven cavity3d41Meat probe shorted3d51Meat probe not calibrated4d11Door switch position failure4d12Door switch position failure4d21No Reverse Airflow Fan rotation (no/low RPM) on upper/single oven cavity.4d22No Reverse Airflow Fan rotation (no/low RPM) on lower oven cavity.4d31Reverse Airflow Fan state error4d32Reverse Airflow Fan state error4d41High Reverse Airflow Fan rotation (high RPM) on upper/single oven cavity.4d42High Reverse Airflow Fan rotation (high RPM) on lower oven cavity.4d51Door switch circuit failure4d52Door switch circuit failure9d11Door latch will not lock on upper/single oven cavityView all 96 error codes
9d12Door latch will not lock on lower oven cavity9d21Door latch will not unlock on upper/single oven cavity9d22Door latch will not unlock on lower oven cavity9d31Door latch both locked and unlocked simultaneously on upper/single oven9d32Door latch both locked and unlocked simultaneously on lower ovendLLid Lock FailuredULid Unlock FailureF-01Primary control failure in the machine control electronics.F-02Stuck button or user interface mismatchF-22Exhaust thermistor is open.F-23Exhaust thermistor has shorted.F-26Motor drive system failure.F-28Moisture sensor strip is openF-29Moisture sensor strip has shortedF-30Restricted air flow condition existsF-50No voltage detected at the water valve relay (steam model)F1Pressure Signal Out-of-RangeF1E1Indicates a Cycle Control Unit (CCU) problem.F1E2MCU errorF2Keypad/User Interface FailureF2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F2E2User Interface software errorF2E3Unsupported cycleF3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<20 ohms).F3E5Inlet and exhaust thermistors are open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F40ATC Thermistor Open/ShortF41Motor RPS Thermistor Open/ShortF4E0Heater is not detectedF4E1No voltage detected at the heater relay; only appears in service diagnostic…F4E3Restricted/low air flow that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at installation.F50Motor StalledF51Motor RPS FailureF52Motor Stop FailureF53Motor Control OvertempF54Motor Control OvercurrentF5E1Door switch errorF5E2Door lock errorF5E3Door unlock errorF6E1Communication error between CCU and MCUF6E2Communication error UI to CCUF6E3Communication error CCU to UIF72Basket Re-engagement FailureF7E1Drive motor speed sensing error / washer overloadF7E2MCU overheat and/or motor overheatF8E0Steam inlet valve errorF8E1No water detected entering washer or pressure sensor trip not detectedF8E3Overflow conditionF9E1Long drainHCHot, Cold ReversedL2Low L2 voltage (less than 50V) detected at installation.LdLong DrainLFLong FilllidOpen/Close LidoLOverloadedPFPower failure occurred while the dryer was running.PoPump OutrLLoad detected during the washer cleaning cycle (remove load); saved as F0E1.SdSuds DetectionSudSuds detecteduLUnbalanced Load
Service modes (30)
- Automatic Diagnostic Test Mode["Ensure washer is in standby mode (plugged in with all indicators off, or with only Clothes Clean…
- Console and Indicators Diagnostic Test Mode["Plug in washer or reconnect power.","From Standby (Off) Mode, press and release the following…
- customer_focused_drying_mode_adjustment1
- Customer-Focused Dryness Level Adjustment1
- Diagnostic Code Display Mode (H1 Controls)Press and hold AUTOSET pad for 3 seconds at power-up.
- Diagnostic Code Display Mode (H3 Controls)Press and hold Upper Cancel and Timer for 3 to 5 seconds within 5 minutes of power up.
- Diagnostic Code Display Mode (NSC Controls)Press and hold the More + pad for 3 to 5 seconds when powering up the unit (within 60 seconds of…
- diagnostic_test_mode1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Done…
- display_line_voltageAfter all saved fault codes have been displayed in diagnostic test mode, press the End of Cycle…
- Fault/Error Code Display["Activate Service Diagnostic Mode first.","Press and release the 3rd button used to activate…
- Faults Access (EOC III Controls)1
- Install Diagnostics1
- Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
- Manual Diagnostic Test Mode["Perform steps 1 and 2 of Automatic Diagnostic Test Mode entry (press/hold/release…
- manual_load_test1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Done…
- One-Watt Standby Mode (NSC Controls)Press and hold Cancel and Less
- Quick Diagnostic Test["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- Quick Test Mode (EOC III Controls)1
- Quick Test Mode (H1 Controls - Convection Model)1
- Quick Test Mode (H1 Controls - Non-Convection Model)1
- Quick Test Mode (H2/H2.5 Controls)1
- Quick Test Mode (H3 Controls)1
- Quick Test Mode (M1/M2 Controls)1
- Quick Test Mode (NSC Non-Self Clean Controls)1
- Service Diagnostic Mode1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
- Service Mode (EOC III Controls)1
- Software Version Display1
- Test Mode (UH Controls)1
- User Interface Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
- User Interface/Control System Test1. Activate Service Diagnostic Mode. 2. Press and release the 1st button used to activate Service…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana freezer models
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax