7 documents12 error codes3 service modes
Available documentation
Tech Sheet
- Amana Jennair Microwave AMV6167BD JMV8166BA JMV9169BA Tech Sheet11 pg
Service Manual
- Service Manual - Over-the-Range Domestic Microwaves80 pg
- 2006 Over-the-Range Domestic Microwaves Base Manual80 pg
- Over-the-Range Domestic Microwaves Service Manual80 pg
Service Flash
- Installation Bulletin - IDM-0001-B OTR Exhaust Options_IDM-0001-B1 pg
Bulletin
- Technical Bulletin - TDM-0011B-B OTR Microwave Assembly Mounting Hardware Kit1 pg
Installation Guide
- Installation Bulletin - IDM-0001-B-French OTR Exhaust Options1 pg
MyPros+ Max
Diagnose your Maytag JMV9169BA.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (12)
CodeMeaning
E03Convection motor or convection heater open circuit detected.E11Gas sensor open error.E12Gas sensor short error.E13T1 Max time errorE21Thermal sensor open error.E22Thermal sensor short error.E23Preheat did not reach preset temperature within 30 minutes; preheat cycle…E24Microwave temperature reaches 500°F (260°C) in an overheat condition; microwave…E61Sensor open error.E62Sensor shorted error.E63T1 Max Time error.SEKeypad shorted for 10 seconds or longer, indicating sticky keypad(s).Service modes (3)
- Control Panel Sensor Test1
- Sensor test (AMV6167BD*)Apply power to microwave for 5 minutes
- Sensor test (JMV8166BA*, JMV9169BA*)Apply power to microwave for 5 minutes
Full entry steps, exit procedures, and test sequences are available in Max.