Model reference
Maytag UMV1152CAQ
Microwave
7 documents12 error codes1 service mode
Available documentation
Tech Sheet
- techsheet-w10182258.pdf1 pg
- Domestic Microwave—Technical Information6 pg
Service Manual
- 2006 Over-the-Range Domestic Microwaves Base Manual80 pg
- Over-the-Range Domestic Microwaves Service Manual80 pg
Service Flash
- Electronic Control Board (light circuit) failure due to the oven cavity light bulb socket shorting out4 pg
Other
- TDM 0011 B1 pg
- 1602712880 pg
MyPros+ Max
Diagnose your Maytag UMV1152CAQ.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (12)
CodeMeaning
E03Convection motor or convection heater circuit is open.E11Gas sensor open error.E12Gas sensor short error.E13T1 Max time errorE21Thermal sensor open error.E22Thermal sensor short error.E23Preheat did not reach preset temperature within 30 minutes; preheat cycle…E24Microwave temperature reaches 500°F (260°C) in overheat condition; microwave…E61Sensor open error.E62Sensor shorted error.E63T1 Max Time error.SEKeypad shorted for 10 seconds or longer, indicating sticky keypad(s).Service modes (1)
- Control Panel Sensor Test1
Full entry steps, exit procedures, and test sequences are available in Max.