Model reference
Maytag JES9860ACB/S/W
Range
2 documents18 error codes1 service mode
Available documentation
Service Manual
- Electric Slide-In Range Service Manual55 pg
- Electric Slide-In Range Service Manual55 pg
MyPros+ Max
Diagnose your Maytag JES9860ACB/S/W.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (18)
CodeMeaning
F0-0No fault present.F1-1Oven temperature above 650°F (343°C) in bake mode.F1-3Oven temperature above 950°F (510°C) during a clean cycle.F1-5Cancel pad not responding.F1-7Membrane disconnected.F1-8Shorted key (pad) in membrane switch.F1-9Internal control communication errors.F1-ALock/unlock switch state not advancing to control.F1-COven door switch state not advancing to control.F1-EControl not calibrated.F1-FJumper not removed from printed circuit board (PCB).F1-HEEPROM error.F1-NInternal voltage for slave micro incorrect.F3-1Open or shorted oven temperature sensor.F8Shorted meat probe.F9-1Oven door will not lock.F9-2Oven door will not unlock.F9-3Oven door status is both locked and unlocked.Service modes (1)
- Quick Test Mode (EOC II)1
Full entry steps, exit procedures, and test sequences are available in Max.
Related Maytag range models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass