CodeMeaning
F0-0No fault present.F1-1Oven temperature above 650°F (343°C) in bake mode.F1-3Oven temperature above 950°F (510°C) during a clean cycle.F1-5Cancel pad not responding.F1-7Membrane disconnected.F1-8Shorted key (pad) in membrane switch.F1-9Internal control communication errors.F1-ALock/unlock switch state not advancing to control.F1-COven door switch state not advancing to control.F1-EControl not calibrated.F1-FJumper not removed from printed circuit board (PCB).F1-HEEPROM error.F1-NInternal voltage for slave micro incorrect.F3-1Open or shorted oven temperature sensor.F8Shorted meat probe.F9-1Oven door will not lock.F9-2Oven door will not unlock.F9-3Oven door status is both locked and unlocked.Service modes (3)
- Quick Test Mode1
- Setup Options / Factory Default Change Mode1
- View Most Recent Fault Code1