Model reference
Maytag MGR8800DE2
Range
7 documents13 error codes15 service modes
Available documentation
Tech Sheet
- Tech Sheet - W10538797 - Rev A8 pg
- Tech Sheet - W10538798 - Rev A (FR)8 pg
Service Flash
- Whirlpool Range Service Pointer W10702913A Revised6 pg
- Service Pointer - W10702913 - Rev A (Bake Burner May Not Ignite)6 pg
Installation Guide
- Installation Instructions40 pg
Quick Reference
- Quick Reference Manual2 pg
- Oven Cleaning Quick Reference Guide2 pg
MyPros+ Max
Diagnose your Maytag MGR8800DE2.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (13)
CodeMeaning
F1-E0EEPROM communication error.F1-E5Sensor out of range.F1-E7PCB thermistor open or shorted.F2-E0Keypad disconnected.F2-E1Stuck key.F2-E2Cancel key error.F3-E0Main oven temperature sensor open or shorted.F3-E2Warming drawer sensor open or shorted.F5-E0Door and switches do not agree (Clean modeF5-E1Door latch not operating (Clean modeF6-E1Over temperature during cook mode.F6-E2Over temperature during clean mode.F6-E3Over temperature in warming drawer.Service modes (15)
- Auto Test1
- CONTROL RESET["Enter diagnostic mode
- Diagnostic / Service Mode["Press CANCEL > CANCEL > START.","Display shows 'TEST ON' with oven cavity temperature and door…
- Diagnostics Mode / Service Mode EntryPress CANCEL > CANCEL > START
- DISPLAYEnter Service Mode (CANCEL > CANCEL > START), scroll to step 5 (DISPLAY).
- ENG MODEEnter Service Mode (CANCEL > CANCEL > START), scroll to step 2 (ENG MODE)
- ENG MODE (Engineering Mode)["Enter diagnostic mode
- FAULTSEnter Service Mode (CANCEL > CANCEL > START), scroll to step 7 (FAULTS).
- RELAY USAGEEnter Service Mode (CANCEL > CANCEL > START), scroll to step 8 (RELAY USAGE).
- Temperature Adjustment1
- TEST MODEEnter Service Mode (CANCEL > CANCEL > START), scroll to step 3 (TEST MODE)
- TEST MODE (Relay Test)["Enter diagnostic mode
- TEST ON (Relay Checks)Upon entering Service Mode (CANCEL > CANCEL > START), 'TEST ON' is displayed
- USAGEEnter Service Mode (CANCEL > CANCEL > START), scroll to step 1 (USAGE).
- VERSIONEnter Service Mode (CANCEL > CANCEL > START), scroll to step 4 (VERSION).
Full entry steps, exit procedures, and test sequences are available in Max.
Related Maytag range models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass