Model reference
Maytag YMER7662WW1
Range
6 documents25 error codes8 service modes
Available documentation
Tech Sheet
- Fiche technique - Tech Sheet8 pg
Service Manual
- Troubleshooting Gas and Electric Freestanding Range Electronic Controls70 pg
Service Flash
- Technical Service Pointer - W10412840 (Passive Door Hinge Design)6 pg
- Technical Service Pointer - W10473748 (F9 E0 Error Code)6 pg
Installation Guide
- Installation Instructions16 pg
- Instruction Sheet2 pg
MyPros+ Max
Diagnose your Maytag YMER7662WW1.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (25)
CodeMeaning
F1Internal circuit board failure or A/D error(s)F1 E*Control board failure (all F1 sub-codes indicate control fault).F1E0Internal circuit board failure.F1E1Internal circuit board A/D error.F1E2Internal circuit board A/D error.F2Shorted key on the touch panel.F2E0Shorted key on the touch panel.F3Oven sensor open circuit, short circuit, or excessive temperature during…F3 E0Oven temperature sensor fault (open or shorted)F3 E1Lower oven temperature sensor fault (MRC II double oven models).F3 E2Warming drawer temperature sensor fault.F3E0Oven sensor open circuit.F3E1Oven sensor short circuit.F3E2Bake/broil excessive temperature.F3E3Clean mode excessive temperature.F5Door and latch switch mismatch during clean mode.F5 E0Door position switch faultF5 E1Door latch switch/system faultF5 E2Door switch fault.F5E0Door and switch mismatch during clean mode.F5E1Door latch does not function during clean mode.F5E2Door and switch mismatch during clean mode.F6 E*Control communication failure.F9Defective housing wiring or defective range wiring.F9E0Defective housing wiring or defective range wiring.Service modes (8)
- diagnosticPress CANCEL > CANCEL > START within 5 seconds.
- diagnostic_test_modeWhile in diagnostic mode, press individual function buttons to test each relay
- LCC Diagnostic Mode (LCC90/LCC95/LCC180)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- LCC190 Diagnostic Mode (Self Clean, Convection models)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME or TEMP/HOUR '+' key to cycle through…
- MRC Diagnostic Mode["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- MRC Diagnostic Mode (Fan/True Convection Electric - Oven Light entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- MRC II Diagnostic Mode (Number 3 key entry - KitchenAid models)["Press OFF/OFF/START or CANCEL/CANCEL/START in sequence.","Press the number '3' key to cycle…
- MRC II Diagnostic Mode (TEMP/TIME entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' keypad to cycle through diagnostic…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Maytag range models
78,000+ service manuals · 160,000+ error codes · 55+ brands