Model reference
Maytag YMER8875WW0
Range
5 documents20 error codes9 service modes
Available documentation
Tech Sheet
- Tech Sheet - W10239471 - Rev A (FR)8 pg
- Tech Sheet - W10239470 - Rev A8 pg
Service Manual
- Troubleshooting Gas and Electric Freestanding Range Electronic Controls70 pg
Service Flash
- Service Pointer - 4317472 (Oven Rack Falling)2 pg
Installation Guide
- Installation Instructions12 pg
MyPros+ Max
Diagnose your Maytag YMER8875WW0.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (20)
CodeMeaning
E0Keypad disconnected (F2).E0 E5 E7 E9Internal board fault.E1Stuck key (F2).E2Cancel key error (F2).F1Keypad disconnected (E0), stuck key (E1), or Cancel key error code (E2).F1 E*Control board failure (all F1 sub-codes indicate control fault).F2Control board internal fault (sub-codes E0, E5, E7, E9).F3Oven sensor opened or oven sensor shorted.F3 E0Main oven temperature sensor open or shorted.F3 E1Lower oven temperature sensor fault (MRC II double oven models).F3 E2Warming drawer sensor open or shorted.F5 E0Door and door switch mismatch (clean mode).F5 E1Door latch not functioning (clean mode).F5 E2Door switch fault.F6 E*Control communication failure.F6 E0Extended communication loss (wired).F6 E1BakeF6 E2CleanF6 E3Warming drawerF9House miswiredService modes (9)
- diagnosticWith oven not in bake, broil, or clean mode
- Diagnostics ModeWith oven not in cooking, broiling, or cleaning mode, press CANCEL > CANCEL > START within a 5…
- LCC Diagnostic Mode (LCC90/LCC95/LCC180)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- LCC190 Diagnostic Mode (Self Clean, Convection models)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME or TEMP/HOUR '+' key to cycle through…
- MRC Diagnostic Mode["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- MRC Diagnostic Mode (Fan/True Convection Electric - Oven Light entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- MRC II Diagnostic Mode (Number 3 key entry - KitchenAid models)["Press OFF/OFF/START or CANCEL/CANCEL/START in sequence.","Press the number '3' key to cycle…
- MRC II Diagnostic Mode (TEMP/TIME entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' keypad to cycle through diagnostic…
- Temperature AdjustmentPress and hold OVEN LIGHT key for 5 seconds
Full entry steps, exit procedures, and test sequences are available in Max.
Related Maytag range models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass