Model reference
Maytag YMET8665XS00
Range
4 documents30 error codes19 service modes
Available documentation
Tech Sheet
- Tech Sheet - W10311750 - Rev B32 pg
Service Manual
- Troubleshooting Gas and Electric Freestanding Range Electronic Controls70 pg
Installation Guide
- Installation Instructions20 pg
- Instruction Sheet1 pg
MyPros+ Max
Diagnose your Maytag YMET8665XS00.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (30)
CodeMeaning
F1Control failure or UL A/D error(s) detected in the control board.F1 E*Control board failure (all F1 sub-codes indicate control fault).F1 E0EEPROM communication error.F1 E5Sensor usage out of range.F1 E7PCB thermistor/sensor open or shorted.F1 E9WIDE Queue full.F1-E1Upper RTD uncalibrated.F1-E2Lower RTD uncalibrated.F2Shorted/stuck key detected on the control keypad.F2 E1Stuck key.F2 E2Stuck key.F2-E0Keypad disconnected.F3Oven sensor opened or oven sensor shorted.F3 E0Main oven temperature sensor open or shorted (upper oven).F3 E1Lower oven temperature sensor fault (MRC II double oven models).F3 E2Warming drawer temperature sensor fault.F3-E1Main oven temperature sensor open or shorted (lower oven).F5 E0Door position switch faultF5 E1Door latch switch/system faultF5 E2Door switch fault.F5-E0Door and latch switches do not agree (Clean mode).F5-E1Door latch not operating (Clean mode).F6Control communication error.F6 E*Control communication failure.F6 E0Lost communications.F6 E1Over temperature during cook mode (runaway temp).F6 E3Over temperature in warming drawer (runaway temp).F6-E2Over temperature during clean mode (runaway temp).F9House miswiredF9-E0Product is mis-wired.Service modes (19)
- Control Reset (Soft Reset)1
- Diagnostics ModePress CANCEL > CANCEL > START within 5 seconds.
- Display Test1
- Faults (View/Clear Error Codes)1
- LCC Diagnostic Mode (LCC90/LCC95/LCC180)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- LCC Diagnostic Mode (LCC90/LCC95/LCC180/LCC190 - TEMP/TIME controls)["Press CANCEL, CANCEL, START","Press TEMP/TIME '+' key to step through diagnostic screens:","First…
- LCC190 Diagnostic Mode (Self Clean, Convection models)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME or TEMP/HOUR '+' key to cycle through…
- MRC Diagnostic Mode["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- MRC Diagnostic Mode (Fan/True Convection Electric - Oven Light entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- MRC Diagnostic Mode (MRC controls with OVEN LIGHT entry - Fan/True Convection Electric models)["Press CANCEL, CANCEL, START
- MRC Diagnostic Mode (MRC controls with TEMP/TIME keys)["Press CANCEL, CANCEL, START
- MRC II Diagnostic Mode (number '3' key navigation - KitchenAid models)["Press CANCEL, CANCEL, START (or OFF/Off/START)
- MRC II Diagnostic Mode (Number 3 key entry - KitchenAid models)["Press OFF/OFF/START or CANCEL/CANCEL/START in sequence.","Press the number '3' key to cycle…
- MRC II Diagnostic Mode (TEMP/TIME '+' key navigation)["Press CANCEL, CANCEL, START
- MRC II Diagnostic Mode (TEMP/TIME entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' keypad to cycle through diagnostic…
- Semi Automatic Test1
- Test Mode (Manual Relay Activation)1. Enter Diagnostics Mode (CANCEL > CANCEL > START within 5 seconds). 2. Press TEMP/TIME '+' or '-'…
- Usage Mode1
- Version1
Full entry steps, exit procedures, and test sequences are available in Max.
Related Maytag range models
76,000+ service documents · 19,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax