mypros+
Model reference

Midea US-FC70-DS12DSH/C0401E

Washer

1 document30 error codes10 service modes

Available documentation

Service Manual

  • Laundry Washer and dryer combo Service Manual48 pg
    Covers this model
MyPros+ Max

Diagnose your Midea US-FC70-DS12DSH/C0401E.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (30)

CodeMeaning
E10Water level doesn't change within 7 minutes with valves open (no water inlet or…E11Too much water left in the unit at standby or end of cycle (non-drain…E12Water level in drum exceeds a certain level for alarm (water fill overflow).E20Main PCB cannot get pump signal; unit closes valves and stops motor.E21Water level doesn't change within 3 minutes with pump started (drain timeout).E30Door cannot be locked after more than 3 failed attempts.E31Door cannot be unlocked after more than 3 failed attempts.E33Main PCB cannot get water level switch signal.E34Temperature sensor on water heater is open circuit.E35Temperature sensor on water heater is short circuit.E36Water heater doesn't work.E37Drum drying outlet temperature sensor failed; drying function cannot work.E38Drum drying inlet temperature sensor failed; drying function cannot work.E3ADrying heater open circuit; drying function cannot work.E40EEPROM failed; memory chip of the PCB is broken.E50/E52Inverter PCB overload; unit cannot work.E50/E53Inverter module temperature failure; unit cannot work.E50/E55Motor speed signal lost; unit will stop operation.E50/E56Motor temperature over-protection; unit will stop operation.E50/E57Inverter module temperature failure; unit will stop operation.E50/E58Inverter module failure; unit will stop operation.E50/E5AConnection failure between inverter module and main control PCB; unit will stop…E50/E5BInverter module failure; unit will stop operation.E50/E5COver voltage on inverter module; unit will stop operation.E50/E5DLow voltage on inverter module; unit will stop operation.E50/E5EInverter module failure; unit will stop operation.E64Signal between main PCB and inverter PCB is abnormal; unit will stop operation.E70Button blocked/stuck; unit cannot work.E80Main PCB cannot get signal from display PCB; unit cannot work.E81Main PCB cannot get signal from display PCB; unit cannot work.

Service modes (10)

  • t02 - Error Code Review1
  • t04 - Display Test1
  • t05 - Pump Test1
  • t06 - Water Switch Test1
  • t07 - Water Heater Test1
  • t08 - Drying Heater Test1
  • t09 - Wash Function Test1. Enter test mode. 2. Navigate to 't09' display. 3. Press Start/Pause to activate. Display shows…
  • t10 - Spin Function Test1
  • t12 - Water Inlet Valve Test1. Enter test mode. 2. Navigate to 't12' display. 3. Press Start/Pause
  • Test Mode (Diagnostic)1. Shut down the machine by pressing the On/Off button. 2. Disconnect the plug from the power…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass