Model reference
Samsung DV409A
Dryer
1 document9 error codes5 service modes
Available documentation
Service Manual
- Clothes Dryer Service Manual46 pg
MyPros+ Max
Diagnose your Samsung DV409A.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (9)
CodeMeaning
bEInvalid state of key circuit short for 30 seconds on the display PCB.dFDoor sensor circuit has loose or open wire terminals.dORunning the dryer with door open; invalid state for more than 0.25 seconds.EtInvalid state of EEPROM communication.FEInvalid power source frequency detected.hEInvalid heating temperature detected while running the dryer.odInvalid dry time in excess of allowed dry time.tOThe thermistor resistance is very low or high (alternate display for thermistor…tSThe thermistor resistance is very low or high, indicating a temperature sensor…Service modes (5)
- continuous_run_mode1
- cycle_count_mode1
- software_version_mode1
- special_test_mode1
- system_check_mode1. With the dryer powered off (normal user mode), press Dry Level + Power buttons simultaneously…
Full entry steps, exit procedures, and test sequences are available in Max.