Samsung RF268ABPN/XAA-00

Refrigerator

3 documents24 error codes9 service modes

Available documentation

Tech Sheet

  • Fast Track Troubleshooting8 pg
    Covers this model
  • Fast Track Troubleshooting8 pg
    Covers this model
  • Fast Track Troubleshooting7 pg
    Covers this model
MyPros+ Max

Diagnose your Samsung RF268ABPN/XAA-00.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (24)

CodeMeaning
C-FAN ERRORCondenser Fan is not spinning at the correct RPM or the fan feedback line is…COOL SELECT ZONE SENSORCool Select Zone Sensor ErrorDEFROST SENSOR OF R ROOMRefrigerator Defrost Sensor ErrorEXT-SENSORAmbient Temp Sensor ErrorF-DEF-SENSORFreezer Room Defrost Sensor ErrorF-DEFROSTING ERRORFreezer defrost heaterF-FAN ERRORFreezer Evap Fan is not spinning at the correct RPM or the fan feedback line is…F-SENSORFreezer Compartment Sensor ErrorFRENCH DOOR ICE ROOM FAN ERRORIce Room Compartment Evap Fan is not spinning at the correct RPM or the fan…FRENCH DOOR ICE ROOM SENSORIce Room Sensor ErrorI/M FUNCTION ERRORIce tray has not returned to level after an ice harvest; error displayed after…I/M FUNCTION ERROR (F)Ice tray has not returned to level after an ice harvest (Freezer side); error…I/M-SENSORIce Maker Sensor Error (Fridge side on Twin I/M units)I/M-SENSOR (F)Ice Maker Sensor Error (Freezer side on Twin I/M units)ICE PIPE HEATER ERRORIce maker fill pipe heater is open or shorted.L↔M ERROR COMMUNICATIONCommunication error within the Main PCB.P↔M ERROR COMMUNICATIONCommunication error between the Main PCB and Keypad.PANTRY-DAMPER-HEATER ERRORPantry room damper heater error.PANTRY-SENSOR ERRORCR Room (Pantry) Sensor ErrorR-DEFROSTING ERRORRefrigerator Room defrost heaterR-FAN ERRORRefrigerator Evap Fan is not spinning at the correct RPM or the fan feedback…R-SENSORRefrigerator Room Sensor ErrorUart ERROR COMMUNICATIONNot applicable; if detected during diagnostic testing, ignore it.WATER HEATER ERRORWater reservoir tank heater is open or shorted.

Service modes (9)

  • Forced Mode (Compressor/Defrost Test)Press both Energy Saver and Fridge buttons simultaneously (no sound when pressed at the same time)
  • Forced Mode (Forced Freeze/Compressor Test)Press both Energy Saver and Fridge buttons simultaneously (no sound when both pressed at the same…
  • Forced Mode (Test Mode)Press both Energy Saver and Fridge buttons simultaneously (no sound when both buttons are pressed…
  • Heat Release I/M Test ModePress and hold the ICE TEST S/W on the ice maker for at least 1.5 seconds
  • Sales ModePress Energy Saver and Freezer temp buttons simultaneously for 3 seconds (you will hear a 'Ding…
  • Sales Mode (No Compressor Operation)Press Energy Saver and Freezer temp buttons simultaneously for 3 seconds
  • Self DiagnosisPress both Energy Saver and Alarm buttons simultaneously (no sound when both buttons are pressed at…
  • Self Diagnosis (Fault Code Reading)Press both Energy Saver and Alarm buttons simultaneously (no sound when pressed at the same time)
  • Self Diagnosis (Fault Code Readout)Press both Energy Saver and Alarm buttons simultaneously (no sound when both pressed at the same…

Full entry steps, exit procedures, and test sequences are available in Max.