Model reference

Samsung RF268ABWPXAA

Refrigerator

3 documents48 error codes9 service modes

Available documentation

Service Manual

  • Samsung Refrig RF268ABRS ABBP ABWP ABPN RF268AB Service Guide128 pg
    Covers this model
  • Samsung Refrigerator Technical Service Guide128 pg
    Covers this model

Tech Sheet

  • Fast Track Troubleshooting RF268AB AC8 pg
    Covers this model
MyPros+ Max

Diagnose your Samsung RF268ABWPXAA.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (48)

CodeMeaning
C-FAN ERRORCondenser Fan is not spinning at the correct RPM or the fan feedback line is…COOL SELECT ZONE SENSORCool Select Zone Sensor ErrorDEFROST SENSOR OF R ROOMRefrigerator Defrost Sensor ErrorEXT-SENSORAmbient Temperature Sensor ErrorF-1-ⓐAmbient-Sensor errorF-1-ⓑF-Sensor errorF-1-ⓒF-DEF-Sensor errorF-1-ⓓF-FAN errorF-1-ⓔC-FAN errorF-1-ⓕIce Room Sensor errorF-1-ⓖF-DEF heater errorF-10-ⓑIce Room FAN errorF-10-ⓖPanel ↔ Main MICOM communication errorF-DEF-SENSORFreezer Room Defrost Sensor ErrorF-DEFROSTING ERRORFreezer defrost heaterF-FAN ERRORFreezer Evaporator Fan is not spinning at the correct RPM or the fan feedback…F-SENSORFreezer Compartment Sensor ErrorFRENCH DOOR ICE ROOM FAN ERRORIce Room Compartment Evaporator Fan is not spinning at the correct RPM or the…FRENCH DOOR ICE ROOM SENSORIce Room Sensor ErrorI/M FUNCTION ERRORIce tray has not returned to level after an ice harvest; error displayed after…I/M FUNCTION ERROR (F)Ice tray has not returned to level after an ice harvest (Freezer side on Twin…I/M-SENSORIce Maker Sensor Error (Fridge side on Twin I/M units)I/M-SENSOR (F)Ice Maker Sensor Error (Freezer side on Twin I/M units)ICE PIPE HEATER ERRORIce maker fill pipe heater is open or shorted.L↔M ERROR COMMUNICATIONCommunication error within the Main PCB.OP-ErPanel ↔ MAIN MICOM option errorP↔M ERROR COMMUNICATIONCommunication error between the Main PCB and Keypad.PANTRY-DAMPER-HEATER ERRORSensor system in Pantry Room damper heater error.PANTRY-SENSOR ERRORPantry/CR Room Sensor ErrorPc-EPanel ↔ MAIN MICOM communication error displayed on Pantry Room Display.
View all 48 error codes

Service modes (9)

  • Exhibition ModePress Energy Saver Key + Freezer Key simultaneously for 3 seconds during normal operation
  • Forced Mode (Test Mode)Press both Energy Saver and Fridge buttons simultaneously (no sound when both buttons are pressed…
  • Heat Release I/M Test ModePress and hold the ICE TEST S/W for at least 1.5 seconds; the harvest function will start.
  • Load Condition DisplayPress Energy Saver Key + Alarm Key simultaneously for 6 seconds (display blinks ALL ON/OFF for 2…
  • Option Setting ModePress Freezer Key + Alarm Key simultaneously for 12 seconds during normal operation
  • Sales Mode (No Compressor Operation)Press Energy Saver and Freezer temp buttons simultaneously for 3 seconds (you will hear a 'Ding…
  • Self DiagnosisPress both Energy Saver and Alarm buttons simultaneously (no sound when both buttons are pressed at…
  • Self-Diagnostic FunctionPress Energy Saver Key + Alarm Key simultaneously for 8 seconds
  • Test Mode (Manual Operation / Manual Defrost)Press Energy Saver Key + Fridge Key simultaneously for 8 seconds. All displays on the front panel…

Full entry steps, exit procedures, and test sequences are available in Max.

76,000+ service documents · 19,000+ error codes · 100+ brands