4 documents34 error codes17 service modes
Available documentation
Service Manual
- Sub-Zero Revision 1: Prior to Serial 3559999 — Service Manual97 pg
- Sub-Zero Revision Hydrocarbon (7041201): After Serial 3560000 — Service Manual88 pg
Parts Manual
- Sub-Zero Revision Hydrocarbon (7041202): After Serial 3560000 — Parts Manual9 pg
- Sub-Zero Revision 1 (7004859): Prior to Serial 3559999 — Parts Manual8 pg
MyPros+ Max
Diagnose your Sub-Zero ICB648PROG.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (34)
CodeMeaning
01Zone cabinet thermistor failure (device or wiring).02Zone evaporator thermistor failure (device or wiring).03Zone condenser thermistor failure (device or wiring).04Ambient thermistor failure (device or wiring).20Check zone defrost bi-metal for proper operation.21Check zone defrost bi-metal for proper operation.22Check zone defrost wiring.23Check zone defrost wiring.24Check zone defrost heater ohms.30Check for stuck icemaker or water valve failure.35Zone fan speed error.40Zone excessive compressor run time.41Check zone compressor and wiring.42Check condenser fan and/or wiring.43Check left refrigerant valve and wiring.44Check zone glass door heater and wiring.45Errors detectable with red door switches are disabled; check overhead lighting.46Check ice accessory wiring for open circuit.47Check accent lighting wiring for short circuit.80Check power to compressor controller for zone; troubleshoot with manual…83Replace zone variable speed compressor and filter-drier.84Check zone variable speed compressor wiring.85Zone variable speed compressor control overheat.86Check communication wiring, replace zone variable speed controller.87Check for broken wiring or open defrost heater.89Check icemaker solenoid valve and wiring.90Change main control board.91Lighting system failure; check bulbs and wiring.92Check keypad wiring.93Replace keypad.Service modes (17)
- Diagnostics - Activate ZoneAfter initiating Service Mode, press ALARM once, press COLDER three times, press ALARM
- Diagnostics - Clear Error History1) Initiate Service Mode
- Diagnostics - Error HistoryAfter initiating Service Mode, press ALARM once, press COLDER once, press ALARM two times
- Diagnostics - Self TestAfter initiating Service Mode, press ALARM key 3 consecutive times
- Diagnostics - StatisticsAfter initiating Service Mode, press ALARM once, press COLDER four times, press ALARM.
- Diagnostics - Thermistor ReadAfter initiating Service Mode, press ALARM once, press COLDER two times, press ALARM
- Manual Freezer Evaporator DefrostPress and hold the ICE MAKER key for 5 seconds.
- Manual Zone Disable ModeWith unit ON, press and hold the WARMER key for the zone being disabled, then press the POWER key…
- Model InformationAfter initiating Service Mode, press COLDER two times, then press ALARM two times
- Operational Status - Ice MakerAfter initiating Service Mode, press COLDER once, press COLDER once more, press ALARM once
- Operational Status - Zone StatusAfter initiating Service Mode, press COLDER once, then press ALARM twice
- Sabbath ModeSwitch unit OFF using POWER key
- Service ModePress and hold any COLDER key, then press the POWER key, then release both keys.
- Service Mode (Diagnostic)Press and hold any COLDER key, then press the POWER key, then release both keys
- Showroom ModeSwitch unit OFF using POWER key
- Temperature Units Selection ModeMust be done within the first 1 minute after switching unit ON
- Version InformationAfter initiating Service Mode, press COLDER three times, then press ALARM once
Full entry steps, exit procedures, and test sequences are available in Max.