mypros+
Model reference

Sub-Zero ICBID-24RO

Refrigerator

3 documents72 error codes4 service modes

Available documentation

Service Manual

  • Sub-Zero Service Manual: ICBID-24RO — Service Manual55 pg
    Covers this model

Parts Manual

  • Sub-Zero ICB Integrated Drawer Hydrocarbon (7041360): After Serial 5623000 — Parts Manual25 pg
    Covers this model
  • Sub-Zero Revision 1: Prior to Serial 5622999 — Parts Manual24 pg
    Covers this model
MyPros+ Max

Diagnose your Sub-Zero ICBID-24RO.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (72)

View all 72 error codes
15 C 00AC condenser fan relay stuck open15 C 01AC condenser fan relay stuck closed.15 U 00Water valve no current detected15 U 01Water valve current detected20 2 00Defrost bi-metal stuck open.20 2 01Defrost bi-metal stuck closed.20 2 05Defrost bi-metal miswire with normal temperatures.20 2 06Defrost bi-metal miswire with overheating.20 2 50Defrost heater open.30 8 05No signal from ice maker for fill.35 1 00Zone 1 evaporator fan open.35 1 33Zone 1 fan speed faster than setting35 1 34Zone 1 fan speed slower than setting.35 2 00Zone 2 evaporator fan open.35 2 33Zone 2 fan speed faster than setting.35 2 34Zone 2 fan speed slower than setting.35 3 00Zone 3 evaporator fan open.35 3 33Zone 3 fan speed faster than setting.35 3 34Zone 3 fan speed slower than setting.35 A 00Air filter fan open.35 C 00DC condenser fan open.35 C 33DC condenser fan speed faster than setting.35 C 34DC condenser fan speed slower than setting.40 1 00Zone 1 stepper current fault40 1 40Zone 1 excessive compressor runtime.40 1 87Zone 1 stepper cooling fault40 2 00Zone 2 stepper current fault40 2 40Zone 2 excessive runtime.40 2 87Zone 2 stepper cooling fault40 3 40Zone 3 excessive runtime.40 9 40Dispenser max time40 b 00Baffle current fault.40 b 87Baffle cooling/position fault.45 1 00Lights open circuit45 1 01Lights short circuit45 2 00Lights open circuit45 2 01Lights short circuit90 5 80No UIM communications.90 H 80High voltage micro (CCM) no communication90 H 82High voltage micro (CCM) partial communication90 H 83High voltage micro (CCM) bad communication90 H 84High voltage micro (CCM) initialization fault.

Service modes (4)

  • Manual Component Activation["Tap Settings.","Tap Service Options and enter password.","Tap Manual Activation.","Tap the…
  • Sabbath Mode["Tap Settings.","Tap Sabbath Mode.","Touch and hold the screen for 10 seconds to enable."]
  • Service Options Menu["Tap Settings.","Tap Service Options.","Enter the password on the Enter Password screen."]
  • Showroom Mode["Tap Settings.","Tap Service Options.","Enter the Showroom mode password.","Tap Start to enter…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass