Model reference
Sub-Zero ID-36C
Refrigerator
2 documents72 error codes1 service mode
Available documentation
Service Manual
- Sub-Zero Service Manual: Integrated Drawer — Service Manual199 pg
Parts Manual
- Sub-Zero Parts Manual: Integrated Drawers — Parts Manual57 pg
MyPros+ Max
Diagnose your Sub-Zero ID-36C.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (72)
CodeMeaning
10 0 00Condenser thermistor open circuit detected.10 0 01Condenser thermistor short circuit detected.10 0 02Condenser thermistor unstable signal.10 1 00Zone 1 cabinet thermistor open circuit.10 1 01Zone 1 cabinet thermistor short circuit.10 1 02Zone 1 cabinet thermistor unstable signal.10 1 10Zone 1 evaporator thermistor open circuit.10 1 11Zone 1 evaporator thermistor shorted.10 1 12Zone 1 evaporator thermistor unstable signal.10 2 00Zone 2 cabinet thermistor open circuit.10 2 01Zone 2 cabinet thermistor short circuit.10 2 02Zone 2 cabinet thermistor unstable signal.10 2 10Zone 2 evaporator thermistor open circuit.10 2 11Zone 2 evaporator thermistor shorted.10 2 12Zone 2 evaporator thermistor unstable signal.10 3 00Zone 3 cabinet thermistor open circuit.10 3 01Zone 3 cabinet thermistor short circuit.10 3 02Zone 3 cabinet thermistor unstable signal.10 3 10Zone 3 evaporator thermistor open circuit.10 3 11Zone 3 evaporator thermistor shorted.10 3 12Zone 3 evaporator thermistor unstable signal.10 7 00Ambient thermistor on control board open.15 1 00Zone 1 compressor relay stuck open15 1 01Zone 1 compressor relay stuck closed15 2 00Zone 2 compressor relay stuck open15 2 01Zone 2 compressor relay stuck closed15 3 00Zone 3 compressor relay stuck open15 3 01Zone 3 compressor relay stuck closed15 4 00Defrost relay stuck open15 4 01Defrost relay stuck closedView all 72 error codes
15 C 00AC condenser fan relay stuck open15 C 01AC condenser fan relay stuck closed15 U 00Water valve no current detected during activated call for water or dispense.15 U 01Water valve current still detected after valid dispense or ice maker fill20 2 00Defrost bi-metal stuck open.20 2 01Defrost bi-metal stuck closed.20 2 05Defrost bi-metal mis-wire with normal temps20 2 06Defrost bi-metal mis-wire with overheat20 2 50Defrost heater open circuit.30 8 05Icemaker no water valve input signal35 1 00Zone 1 evaporator fan open circuit.35 1 33Zone 1 fan speed set too low35 1 34Zone 1 fan speed set too high35 2 00Zone 2 evaporator fan open circuit.35 2 33Zone 2 fan speed set too low35 2 34Zone 2 fan speed set too high35 3 00Zone 3 evaporator fan open circuit.35 3 33Zone 3 fan speed set too low35 3 34Zone 3 fan speed set too high35 A 00Air filter fan open circuit.35 C 00DC condenser fan open circuit.35 C 33DC condenser fan speed set too low35 C 34DC condenser fan speed set too high40 1 00Zone 1 stepper current fault40 1 40Zone 1 excessive compressor runtime.40 1 87Zone 1 stepper cooling fault40 2 00Zone 2 stepper current fault40 2 40Zone 2 excessive compressor runtime.40 2 87Zone 2 stepper cooling fault40 3 40Zone 3 excessive compressor runtime.40 9 40Dispenser active for maximum fill time40 b 00Baffle stepper current fault.40 b 87Baffle cooling/position fault.45 1 00Lights open circuit45 1 01Lights short circuit45 2 00Lights open circuit45 2 01Lights short circuit90 5 80No UIM (User Interface Module) communications.90 H 80High voltage micro (CCM) no communication90 H 82High voltage micro (CCM) partial communications90 H 83High voltage micro (CCM) bad communications90 H 84High voltage micro (CCM) initialization fault.
Service modes (1)
- Service Options1
Full entry steps, exit procedures, and test sequences are available in Max.